Boiler Maintenance
Cleaning and Maintenance
Fr
öling Boiler and Container Making GmbH, Industriestraße 12, A
-4710 Grieskirchen
page 15
Tel. +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 [email protected]
www.froeling.com
Edition: 02.06.2005
4
IMPORTANT
Cleaning the combustion chamber with the combustion chamber temperature sensor already
mounted.
Hazard. Risk of damage to thermocouple.
Before you start to clean the combustion chamber:
Mark the position of the thermocouple.
Loosen the clamps and pull out the thermocouple.
After maintenance:
Carefully clean any tar or soot deposits from the thermocouple.
Re-insert the thermocouple to the position marked previously and fix in place with the
clamps.
4.1
Inspection, cleaning, and maintenance
For cleaning and maintenance use the cleaning kit provided. The
cleaning kit consists of:
- Chamber plate (triangular plate)
- Flat scraper
- Large brush (
Ø 81 mm)
- Small brush (
Ø 53 mm)
We recommend that you also use an