Fristam Pumps
appropriate Allen
wrench.
g) Place the new gear-
box cover gasket and
gearbox cover on the
gearbox and secure
with the gearbox
cover bolts. Tighten
to the torque speci-
fied in Table A, page
5.
h) Re-install the oil
drain plug and vent
plug onto the gear-
box. Fill the gearbox
with oil to the center
of the oil sight glass.
Once the gearbox is assembled, the pump head can be assembled (pages 16) and the rotor to housing
clearances can be checked. Make any necessary adjustments as required.