- 26 -
v03
Electrical connection:
Connection values
Regarding the cable cross-section:
The current consumption, protection and cross sec-
tion of supply cables depends on:
• Local regulations
• The quality and length of the cable
• The network quality.
They should therefore be adapted to local conditions.
The values indicated are for a cable length of 2m
maximum. It is therefore your responsibility to adapt
these values according to the cable length which you
will use.
Regarding the supply voltage
The permitted tolerance for the supply voltage (input
voltage, see data plate) is between -10 % and
+10 %.
50/60Hz:
Our appliances are compatible with both
frequencies without the need for technical modifi-
cations.
It is strongly recommended not to use a
rigid cable for connection with our appliance.
Maximum size of supply cables
Maximum diameter
(Feeding through the cable glands)
VCCM 112T
Ø Max. 25 mm (1")
VCCM 112L
Ø Max. 32 mm (1 17/64")
Maximum cross-section
(Connection to the supply terminal)
VCCM 112T
Max. 10 mm
2
(0 1/64 in²)
VCCM 112L
Max. 16 mm
2
(0 5/8 in²)
Demonstration mode power
Demo mode* “Reduced”
230 W
Demo mode
*
“On” (full)
115 W
* Demo mode, see chapter “Installation Options”
paragraph “demonstration mode”.
Power
Curent con~
Standardised
Min. recommended
(kW)
sumption (A) protection (A) cross-section (mm
2 )
VCCM 112T
3 AC 200V
17 49
50
10
3 AC 220V
15 39
40
6
3 NAC 400V
17 23
25
2.5
3 NAC 400V Dynamic
13
19
20
2.5
3 NAC 415V
18 25
25
2.5
3 NAC 415V Dynamic
14
19
20
2.5
VCCM 112L
3 AC 200V
28 79
80
16
3 AC 220V
25 66
80
16
3 NAC 400V
28 40
40
6
3 NAC 400V Dynamic
21
30
32
4
3 NAC 415V
30 42
50
10
3 NAC 415V Dynamic
23
31
32
4
Содержание VarioCooking Center 112L
Страница 2: ... 2 v03 ...
Страница 4: ... 4 v03 ...
Страница 13: ... 13 v03 Size of the appliance model 112T with underframe table NB This drawing is not to scale ...
Страница 15: ... 15 v03 Size of the appliance model 112L with underframe table NB This drawing is not to scale ...
Страница 20: ... 20 v03 ...
Страница 35: ... 35 v03 ...