- 28 -
v03
36mm
(1 7/16")
36mm
(1 7/16")
20 - 60 mm
20 - 60 mm
Ø 40mm
Ø 40mm
1
2
435mm
(17 1/8")
498mm
(17 1/8")
527mm
(20 3/4")
594mm
(20 3/4")
DN40
Min. 3%
3
Ø
1 9/16"
Ø
1 9/16"
0 25/32" - 2 3/8"
0 25/32" - 2 3/8"
VCC 112T
VCC 112L
Waste water drainage
Burn hazard!
»
Be careful not to burn yourself,
cooking water may be hot when drai-
ned!
Warning!
• Only use a rigid pipe, resistant to steam tempe-
rature. (PP Type)
• The temperature of waste water is lower than
100 °C
Requirements
• It is forbidden to weld a drainage pipe to the
outlet of the appliance.
• To avoid odour reflux, the drainage pipe should
have a U-bend. Our appliance does not have
one.
• The drainage pipe should be
the same diame-
ter as that of the appliance,
it is not accep-
table to insert a pipe with a smaller diameter.
• The drainage pipe should have a constant slope
of at least 3 %.
Position
VCC112T Fig.1
VCC112L Fig.2
Verifications
After installation of the outlet, fill the tanks with 6
litres of
hot water each
and carry out a test:
» By activating each tank separately.
» Both tanks at the same time.
The water should drain without air bubbles
appearing.
If this is not the case, re-install the outlet or ventilate
the pipes. Example Fig. 3. It is recommended to
carry out the ventilation as close as possible to the
U-bend, for easy elimination of air trapped between
the U-bend and the appliance.