![Frigidaire MFM-6D Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/frigidaire/mfm-6d/mfm-6d_service-manual_115800038.webp)
37
(TROUBLE 3) The oven does not operate at all; Display window does not display any figures and any
inputs can not be accepted.
Condition
Check
Cause
Result
Remedy
Check continuity
Interlock Monitor
switch with door
closed.
Continuity
Malfunction of
Interlock monitor
switch
Replace Primary
Interlock Switch
and Secondary
Interlock Switch
and monitor
Interlock Switch
15A fuse
blows
No
continuity
Check continuity
of both Primary
Interlock Switch
contact with door
partially open until
interlock monitor
switch contact
close.
Continuity
Shorted contacts
of primary inter-
lock switch.
Check continuity
of primary
winding of low
voltage transformer.
0
Ω
or
infinite
Shorted or open
winding
Defective high
voltage transformer
Approx
90-120
Ω
(normal)
Disconnect one
side of the lead
wire connected
from transformer
to the high voltage
capacitor and
operate the unit.
0
Ω
or
infinite
Shorted or open
winding
Defective high
voltage transformer
15A fuse
again blows
Defective high
voltage capacitor
Replace
(Replace 15A fuse)
NOTE 1
Replace Primary
Interlock Switch
and Secondary
Interlock Switch
and monitor
Interlock Switch
NOTE 1
NOTE 1: All these switches must be replaced at the same time, please refer to page 22 and 23 for
adjustment instructions.