32
6. To remove high voltage capacitor.
(1) Remove the screw (F17) which secure the
grounding ring terminal of H.V diode (F20)
and the capacitor holder (F18).
(2) Remove the H.V diode (F20) from the
capacitor holder (F18).
(3) Reverse the above steps for reassembly.
High voltage circuit wiring
7. To remove magnetron.
(1) Remove three screws (F11) holding the
magnetron (F10).
(2) Pull out the magnetron (F10) from the wave
guide.
(3) Reverse the above steps for reassembly.
F20
F18
F17
F19
MAGNETRON
H.V. CAPACITOR
H.V. DIODE
H.V. TRANS
F10
F11