Operating Instructions, Care and Cleaning & Energy Saving Ideas

10

2009 Electrolux Home Products, Inc.

All rights reserved.

Care and Cleaning

Clean your air conditioner occasionally to keep it looking new. 

Be sure to unplug

the unit before cleaning to prevent shock or fire hazards.

Air Directional Louvers

Air directional louvers control air flow direction. Your air conditioner has the louver
type described below.

Auger Type

The louvers will allow you to direct the air flow Up or Down and Left or Right 
throughout the room as needed. Rotate the Auger Wheels until the desired 
Left/Right direction is obtained. Pivot horizontal louvers until the desired 
Up/Down direction is obtained.

AUGER WHEELS

(8-WAY)

Operating Instructions

(continued)

Energy Saving Ideas

Do not block air flow inside with blinds, curtains or furniture; or outside with
shrubs, enclosures, or other buildings.

The capacity of the room air conditioner must fit the room size for efficient and
satisfactory operation.
Install the room air conditioner on the shady side of your home. A window that faces
north is best because it is shaded most of the day.
Close the fireplace damper, floor and wall registers so cool air does not escape up
the chimney and into the duct work.
Keep blinds and drapes in other windows closed during the sunniest part of the day.
Clean the air filter as recommended in the section “Care and Cleaning”.
Proper insulation and weather stripping in your home will help keep warm air out
and cool air in.
External house shading with trees, plants or awnings will help reduce the air
conditioner’s work load.
Operate heat producing appliances such as ranges, washers, dryers and dishwashers
during the coolest part of the day.

Cabinet Cleaning

Be sure to unplug the air conditioner to prevent shock or fire hazard. The
cabinet and front may be dusted with an oil-free cloth or washed with a cloth
dampened in a solution of warm water and mild liquid dishwashing detergent.
Rinse thoroughly and wipe dry.
Never use harsh cleaners, wax or polish on the cabinet front.
Be sure to wring excess water from the cloth before wiping around the controls.
Excess water in or around the controls may cause damage to the air conditioner.
Plug in air conditioner.

Winter Storage

If you plan to store the air conditioner during the winter, remove it carefully from
the window according to the installation instructions. Cover it with plastic or return
it to the original carton.

Air Filter Cleaning

The air filter should be checked at least once a month to see if cleaning is
necessary. Trapped particles in the filter can build up and cause an accumulation
of frost on the cooling coils.

Grasp the filter by the center and pull up and out.

Wash the filter using liquid dishwashing detergent and warm water. Rinse filter
thoroughly. Gently shake excess water from the filter. Be sure filter is
thoroughly dry before replacing

Or instead of washing, you may vacuum the filter clean.

Push the vent handle to the Vent Closed position(where applicable).
Open the front panel.

NOTE:

When replacing the air filter after cleaning, make sure the tabs on the air 

filter are on the upper part of filter, and placed outward as shown in the drawing
on the left side.

Tab

Air Filter

Remark:

 The appearance of actual air filter 

may be slightly different from the line drawing 
shown in the figure. The line drawing is for 
reference only.

Содержание LRA187MT2

Страница 1: ...about the Use Care Care and Cleaning 10 Energy Saving Ideas 10 2020218A1111 June 2009 Product Registration 4 Packaging 4 Normal Sounds 4 Air Conditioner Features 5 Important Safety Instructions 2 3 Operating Instructions 5 10 of your Room Air Conditioner Before You Call 11 Major Appliance Warranty 12 ...

Страница 2: ... result in mechanical damage within the air conditioner Do not use an extension cord or an adapter plug WARNING Electrical Information NOTE The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire Please refer to the section Operation of Current Device for details In the event that the power supply cord is damaged it cannot be repaired...

Страница 3: ... yard away from the unit Do not use or store flammable gases near the unit CAUTION Avoid Injury or damage to the unit or other property Plug in press RESET The power supply cord contains a current device that senses damage to the power cord To test your power supply cord do the following Plug in the Air Conditioner The power supply cord will have TWO buttons on the plug head Press the TEST button ...

Страница 4: ...rect installation Vibration Pinging or Swishing Droplets of water hitting condenser during normal operation may cause pinging or swishing sounds Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Product Registration 4 Prod...

Страница 5: ...d pull to remove battery tray Place battery in tray with POSITIVE side facing UP according to diagram Re insert battery tray Battery Size CR2025 TO REPLACE BATTERY TAB REMOTE CONTROL Air Conditioner Features Operating Instructions Operating Instructions NOTE The following instructions represent the Touch Pad the same instructions can be used for the Remote Control TO TURN UNIT ON YOU WILL SEE PRES...

Страница 6: ...rns to the original set temperature Press either the fan slower or fan faster button to adjust the fan speed manually 2009 Electrolux Home Products Inc All rights reserved YOU WILL SEE Note Tap or hold either up or down button until the desired temperature is seen on the display This tempe rature will be automatically maintained anywhere between 60 F 16 C and 90 F 32 C If you want the display to r...

Страница 7: ...p mode program can be cancelled at any time during operation by again pressing the Sleep button SLEEP FEATURE DO THIS PRESS SLEEP BUTTON YOU WILL SEE Note Use this function only when cooling is not desired such as for room air circulation or to exhaust stale air on some models Remember to open the vent during this function but keep it closed during cooling for maximum cooling efficiency You can ch...

Страница 8: ...n the On position Note For Delay Start the unit must be in the Off position First Press TIMER button then adjust timer setting tap or hold the UP arrow or the DOWN arrow to change delay timer at 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start 8 7 5 7 etc The Delay Start Operation automatically selects cooling wi...

Страница 9: ... Fahrenheit between 60F and 90F degrees There is a 2 Second delay for the compressor shutting down when selecting FAN ONLY This is to cover the possibility of having to roll through to select another mode After a power outage the unit will memorize the last setting and return the unit to the same setting once power is restored Fresh Air Vent Control on some models The Fresh Air Vent allows the air...

Страница 10: ...ad Operate heat producing appliances such as ranges washers dryers and dishwashers during the coolest part of the day Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never us...

Страница 11: ...AN ONLY mode O O Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN ONLY mode Temperature is set too low for night time cooling To defrost the coil set to FAN ONLY mode Then set temperature to a higher setting 11 Room temperature below 60 F 16 C Cooling may not occur until room temperature rises above 60 F 16 C Temperature sensing element touching cold co...

Страница 12: ...ompanies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN CLAIMS BASED ON IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LI...

Отзывы: