background image

OCCURRENCE

SOLUTION

Wall plug disconnected. Push plug firmly into wall outlet.

Plug Current Device Tripped. Press the RESET button.

House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.

Control is OFF. Turn Control ON and set to desired setting.

Air conditioner will not operate.

Air conditioner cooling, but room
is too warm - NO ice forming on 
cooling coil behind decorative
front.

Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.

Temperature is set too high. Set temperature to a lower setting.

Air directional louvers positioned improperly. Position louvers for better air distribution.

Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in
front of unit.

Doors, windows, registers, etc. open - cool air escapes. Close doors, windows, registers, etc.

Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling,
floor and furniture.

Air conditioner turns on and off
rapidly.

Dirty air filter - air restricted. Clean air filter.

Outside temperature extremely hot. Set FAN speed to a faster setting to bring air through cooling coils 
more frequently.

Before You Call

Air conditioner cooling, but room 
is too warm - ice forming
on cooling coil behind decorative
front

Outdoor temperature below 60  F (16  C). To defrost the coil, set FAN ONLY mode.

O

O

Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY 
mode.

Temperature is set too low for night-time cooling. To defrost the coil, set to FAN  ONLY mode. Then, 
set temperature to a higher setting.

11

Room temperature below 60°F (16°C). Cooling may not occur until room temperature rises above 
60°F (16°C).

Temperature sensing element touching cold coil, located behind air filter. Straighten away from coil.

Air from unit does not feel cold
enough.

Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to 
restart when set in the COOL mode.

Reset to a lower temperature.

Noise when unit is cooling.

Air movement sound. This is normal. If too loud, set to lower FAN setting.

2009 Electrolux Home Products, Inc.

All rights reserved.

Water dripping INSIDE when
unit is cooling.

Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to
installation instructions or check with installer.

Water dripping OUTSIDE when
unit is cooling.

Unit removing large quantity of moisture from humid room. This is normal during excessively humid
days.

Room too cold.

Set temperature too low. lncrease set temperature.

Window vibration - poor installation. Refer to installation instructions or check with installer.

Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not 
the result of defective workmanship or materials in this appliance.

If These Solutions Fail, Call 1-888-775-6937 For Frigidaire Service.

Содержание LRA187MT2

Страница 1: ...about the Use Care Care and Cleaning 10 Energy Saving Ideas 10 2020218A1111 June 2009 Product Registration 4 Packaging 4 Normal Sounds 4 Air Conditioner Features 5 Important Safety Instructions 2 3 Operating Instructions 5 10 of your Room Air Conditioner Before You Call 11 Major Appliance Warranty 12 ...

Страница 2: ... result in mechanical damage within the air conditioner Do not use an extension cord or an adapter plug WARNING Electrical Information NOTE The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire Please refer to the section Operation of Current Device for details In the event that the power supply cord is damaged it cannot be repaired...

Страница 3: ... yard away from the unit Do not use or store flammable gases near the unit CAUTION Avoid Injury or damage to the unit or other property Plug in press RESET The power supply cord contains a current device that senses damage to the power cord To test your power supply cord do the following Plug in the Air Conditioner The power supply cord will have TWO buttons on the plug head Press the TEST button ...

Страница 4: ...rect installation Vibration Pinging or Swishing Droplets of water hitting condenser during normal operation may cause pinging or swishing sounds Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Product Registration 4 Prod...

Страница 5: ...d pull to remove battery tray Place battery in tray with POSITIVE side facing UP according to diagram Re insert battery tray Battery Size CR2025 TO REPLACE BATTERY TAB REMOTE CONTROL Air Conditioner Features Operating Instructions Operating Instructions NOTE The following instructions represent the Touch Pad the same instructions can be used for the Remote Control TO TURN UNIT ON YOU WILL SEE PRES...

Страница 6: ...rns to the original set temperature Press either the fan slower or fan faster button to adjust the fan speed manually 2009 Electrolux Home Products Inc All rights reserved YOU WILL SEE Note Tap or hold either up or down button until the desired temperature is seen on the display This tempe rature will be automatically maintained anywhere between 60 F 16 C and 90 F 32 C If you want the display to r...

Страница 7: ...p mode program can be cancelled at any time during operation by again pressing the Sleep button SLEEP FEATURE DO THIS PRESS SLEEP BUTTON YOU WILL SEE Note Use this function only when cooling is not desired such as for room air circulation or to exhaust stale air on some models Remember to open the vent during this function but keep it closed during cooling for maximum cooling efficiency You can ch...

Страница 8: ...n the On position Note For Delay Start the unit must be in the Off position First Press TIMER button then adjust timer setting tap or hold the UP arrow or the DOWN arrow to change delay timer at 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start 8 7 5 7 etc The Delay Start Operation automatically selects cooling wi...

Страница 9: ... Fahrenheit between 60F and 90F degrees There is a 2 Second delay for the compressor shutting down when selecting FAN ONLY This is to cover the possibility of having to roll through to select another mode After a power outage the unit will memorize the last setting and return the unit to the same setting once power is restored Fresh Air Vent Control on some models The Fresh Air Vent allows the air...

Страница 10: ...ad Operate heat producing appliances such as ranges washers dryers and dishwashers during the coolest part of the day Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never us...

Страница 11: ...AN ONLY mode O O Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN ONLY mode Temperature is set too low for night time cooling To defrost the coil set to FAN ONLY mode Then set temperature to a higher setting 11 Room temperature below 60 F 16 C Cooling may not occur until room temperature rises above 60 F 16 C Temperature sensing element touching cold co...

Страница 12: ...ompanies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN CLAIMS BASED ON IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LI...

Отзывы: