background image

2

CABINET
BOTTOM

CABINET FRONT

HORIZONTAL DUCT

ACCESS HOLE

5¼"

5¼"

7½"

1/8

"

¾"

13

15/16

(30" hood)

16

15/16

(36" hood)

13

15/16

(30" hood)

HOOD

MOUNTING

SCREWS (4)

ELECTRICAL

ACCESS HOLE

(in wall)

3¾"

16

15/16

(36" hood)

CENTER

LINE

WOOD SHIMS

(recessed-bottom

cabinets only)

19

15/16

(42" hood)

19

15/16

(42" hood)

SOFFIT

24" - 30" ABOVE
COOKING SURFACE

CABINET

3¼" X 10" DUCT
(For horizontal discharge)

WALL CAP

ROOF CAP

3¼" X 10" or 

7" ROUND DUCT 

(For vertical 

discharge)

HOUSE WIRING
(Top or Back of hood)

HOOD

HOOD

HOOD

PREPARE HOOD LOCATION

PREPARE THE HOOD

1

Remove 

7” Round Duct Plate

 from top of hood. Set duct

plate aside - with mounting screws.

2

Remove tape holding 

Filters

 in place. Pull down on filter

tabs or finger holes and lift filters out. Set filters aside.

7” ROUND

DUCT PLATE

FILTERS

1

Determine whether hood will discharge vertically (3¼” x 10”
or 7” Round), or horizontally (3¼” x 10” only). For vertical or
horizontal discharge, run ductwork between the hood loca-
tion and a roof cap or wall cap. For best results, use a mini-
mum number of transitons and elbows.

2

Use diagrams, below, for proper placement of ductwork and
electrical cutout in cabinet or wall. For a non-ducted installa-
tion, DO NOT cut a duct access hole.

3

Run house wiring between service panel and hood
location.

VERTICAL DUCT

ACCESS HOLE

1¼"

1½"

10½"

5¼"

5¼"

CENTER

LINE

HOOD MOUNTING SCREWS (4)

ELECTRICAL

ACCESS HOLE

(in cabinet bottom)

WOOD SHIMS

(recessed-bottom

cabinets only)

CABINET FRONT

CABINET BOTTOM

13

15/16

(30" hood)

16

15/16

(36" hood)

7½"

5"

2"

19

15/16

(42" hood)

13

15/16

(30" hood)

16

15/16

(36" hood)

19

15/16

(42" hood)

PREPARE HOOD LOCATION

3¼” X 10”

VERTICAL DUCTING

7” ROUND

VERTICAL DUCTING

3¼” X 10”

HORIZONTAL DUCTING

Содержание GL30WC41E

Страница 1: ...ISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels violent ste...

Страница 2: ...lters aside 7 ROUND DUCT PLATE FILTERS 1 Determine whether hood will discharge vertically 3 x 10 or 7 Round or horizontally 3 x 10 only For vertical or horizontal discharge run ductwork between the hood loca tion and a roof cap or wall cap For best results use a mini mum number of transitons and elbows 2 Use diagrams below for proper placement of ductwork and electrical cutout in cabinet or wall F...

Страница 3: ... 3 8 screws and 2 8 screws Disconnect light assembly wire harness white connector 3 8 SCREWS LIGHT PANEL 2 8 SCREWS The following Steps 6 thru 14 are for DUCTED INSTALLATION ONLY BAFFLE 7 Remove Air Chute held in place with one 1 screw NOTE Be careful not to disconnect any wires 9 Rotate baffle Reinsert baffle into air chute as shown so that baffle tabs fit all the way into slots in air chute An a...

Страница 4: ...est to Top Back Edge of hood DAMPER DUCT CONNECTOR Vertical discharge position shown TAPE UP TO 1 SIDE TO SIDE ADJUSTMENT PIVOT TOP BACK EDGE NOTE To accomodate off center ductwork the Damper Duct Connector can be installed up to 1 inch on either side of hood center or the 7 Round Duct Plate can be installed up to on either side of hood center In extreme off center installations one end of the duc...

Страница 5: ...o house wiring GREEN GROUND SCREW INSTALL HOOD KEYHOLE 4 MOUNTING SCREW 4 1 Hang hood from 4 Mounting Screws Slide hood towards wall until mounting screws are engaged in narrow end of 4 Keyholes Tighten mounting screws securely A long screwdriver works best 5 Replace filters turn on power at service panel and test for proper operation 3 Connect ductwork to hood Use Duct Tape to make joints secure ...

Страница 6: ...at Sentry will auto matically turn the fan on at its highest speed when the temperature is above normal 1 If a fan setting is selected when the Heat Sentry in on the light above the fan button will flash on and off 2 If the fan setting is off when the Heat Sentry is on the light above fan button 3 will flash on and off rapidly After the temperature has lowered to normal the fan will change to the ...

Страница 7: ...re 15 Baffle 16 Screw Metric M4 x 6mm 4 in package 17 Motor Plate Includes Key No 18 18 Motor Plate Mounting Kit 3 of each part 19 Motor includes Key No 16 20 Blower Wheel Includes Key No 21 21 Retaining Ring 22 Lamp Socket Assembly 23 Light Panel 24 Hole Plug 1 req 25 Pop Rivet 125D 3 req 26 Filter Spring Kit 27 Bottom Cover includes Key Nos 9 25 26 28 Autotransformer includes hardware 29 Aluminu...

Страница 8: ...mpanies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN CLAIMS BASED ON IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIM...

Страница 9: ...ACEDECUISSON SUIVEZ CES DIRECTIVES 1 ÉTOUFFEZ LES FLAMMES avec un couvercle hermétique une tôle à bis cuits ou un plateau en métal puis éteignez la cuisinière PRENEZ GARDE AUX BRÛLURES Si vous ne parvenez pas à éteindre immédiatement les flammes ÉVACUEZ LES LIEUX ET CONTACTEZ VOTRE POSTE LOCAL DE LUTTE CONTRE LES INCENDIES 2 NE VOUS EMPAREZ JAMAIS D UN PLAT QUI S EST ENFLAMMÉ Vous risqueriez de vo...

Страница 10: ...it de 8 3 cm x 25 4 cm et une installation sans conduit Pour les in stallations à évacuation horizontale ou verticale reliez la hotte à un capuchon de mur ou à un capuchon de toit à l aide de conduits appropriés Pour obtenir de meilleurs résultats évitez dans la mesure du possible d utiliser des transitions ou des coudes 2 Consultez les schémas ci dessous pour savoir où percer les ouvertures dans ...

Страница 11: ...enu par cinq 3 8 vis et 2 8 vis PANNEAU D ÉCLAIRAGE 3 8 VIS 2 8 VIS 8 Enlevez le déflecteur de la chute d air 9 Faites pivoter le déflecteur Réinsérez le déflecteur dans la chute d air comme montré de sorte que les onglets toute la manière dans des fentes dans la chute d air Un clic audible sera entendu quand il est entièrement installé Ceci dirigera l air traversant les fentes non canalisées sur ...

Страница 12: ...jet d air à l horizontale de 8 3 cm x 25 4 cm 13 Pour évacuation horizontale seulement Retirez la plaque qui protège la débouchure pour évacuation horizontale Coupez les attaches puis retirez et jetez la plaque NE RETIREZ PAS la languette de métal maintenue en place par les deux vis ATTACHES PLAQUE LANGQUETTE DE MÉTAL VIS DÉBOUCHURE SUPÉRIEURE POUR CONDUIT RECTANGULAIRE Retirez pour installer un c...

Страница 13: ... 2 ampoules régulières R16 de 40 W maximum ampoules vendues séparément Avertissement Les ampoules peuvent devenir très chaudes Consultez les directives sur l emballage pour plus d information BRANCHEZ LES FILS D ALIMENTATION ÉLECTRIQUE AVERTISSEMENT Afin de prévenir les risques d électrocution assurez vous que le courant ait été interrompu au panneau d alimentation principal Verrouillez ce dernier...

Страница 14: ...qui surveille la température Le détecteur de chaleur metautomatiquementleventilateurenmarcheàlavitessemaximalelorsque la température excède la normale 1 Si l un des réglages du ventilateur est sélectionné alors que le détecteur de chaleur est activé le voyant lumineux situé au dessus du bouton du ventilateur se met à clignoter 2 Sileventilateurestréglésur arrêt alorsqueledétecteurdechaleurest acti...

Страница 15: ... Vis métrique M4 x 6 mm 4 17 Plaque moteur avec clé 18 18 Ensemble plaque moteur 3 exemplaires de chaque composante 19 Moteur avec clé 17 20 Roue du ventilateur avec clé 22 21 Anneau de compression 22 Ensemble de douille de lampe 23 Panneau d éclairage 24 Prise de trou 1 nécessaire 25 Rivet 32 mm 3 nécessaires 26 Ressort pour le filtre 27 Couvercle protecteur sous la hotte avec clés 9 25 et 26 28 ...

Страница 16: ...autorisé ou les causes étrangères comme l abus l alimentation électrique inadéquate ou les cas de force majeure AVIS DE NON RESPONSABILITÉ SUR LES GARANTIES IMPLICITES LIMITATIONS DES RECOURS L UNIQUE RECOURS DU CLIENT EN VERTU DE CETTE GARANTIE LIMITÉE EST LA RÉPARATION OU LE REMPLACEMENT DU PRODUIT COMME DÉCRIT PRÉCÉDEMMENT LES DEMANDES BASÉES SUR DES GARANTIES IMPLICITES Y COMPRIS LES GARANTIES...

Отзывы: