INSTALLING YOUR APPLIANCE
INSTALLING YOUR APPLIANCE
WARNING
WARNING
To avoid any potential hazard, you must follow our
instructions when you install your appliance. Failure
to install the appliance correctly could invalidate any
warranty or liability claims.
• This appliance must be installed by an authorised
person according to all codes and regulations of:
Electrical supply authorities Building regulations
Local government and council authorities .
• Refer to data plate for rating information. The data
plate is positioned behind the bottom of the oven
door.
• A means of disconnection with a contact separation
of at least 3mm must be supplied in the fixed wiring.
• This range must be connected with cable of 75°C
rating minimum.
• This product has passed the insulation resistance
test after manufacture. If the resistance reading is
low at installation, it is probably caused by moisture
from the atmosphere being absorbed by the
elements after the range has been produced.
WARNING
WARNING
This appliance must be properly earthed.
• Do not lift the appliance by the door handles.
• Prepare the cupboard opening to match your
appliance measurements. (See diagrams)
• Slide appliance into the cupboard, ensuring that the
supply cable (where fitted) does not kink.
• To prevent tipping, use the screws supplied to secure
your oven into the cupboard. Use just 2 screws for
underbench.
• For appliances fitted with a flexible supply cord, if
the cord is damaged, it must be replaced by the
manufacturer or its service agent or similarly qualified
person in order to avoid a hazard. The plug must be
accessible after installation.
• Where the appliance is built into a cabinet, the
cabinet material must be capable of withstanding
70°C. Installation into low temperature tolerant
cabinetry (e.g. vinyl coated) may result in
deterioration of the low temperature coating by
discolouring or bubbling.
• If the appliance is installed adjacent to vinyl-wrapped
surfaces, use an installation kit available from the
vinyl-wrap supplier.
• Electrolux Home Products cannot accept
responsibility for damage caused by installation into
low temperature tolerant cabinets.
• After installation, test and ensure that the appliance
operates correctly before handing it over to the
customer. It is recommended that this product is not
installed in an unvented living space, particularly if
that space incorporates sleeping quarters.
MODEL
PRODUCT DIMENSIONS
(H X W X D) MM
MIN FUSE
RATING
MAX POWER
RATING
MAX CURRENT
RATING
WIRE SECTION
(MM²)
FRVE614
597 x 596 x 569
16A
2.0kW
9.1A
2.5
FRVE615
597 x 596 x 569
16A
2.9kW
13.1A
2.5
FRVEP615
597 x 596 x 573
16A
2.7kW
12.4A
2.5
Note: Electrical connection is 220 volts AC 60Hz. Wiring minimum temperature rating 75°C.
INSTALLING YOUR APPLIANCE
• If a powerpoint is fitted it must be accessible with the
appliance installed, as the plug must be accessible
after installation.
• This appliance must be mounted on a flat surface for
the full width and depth of the product.
• To avoid overheating, the appliance must not
be installed in a recess or cupboard behind a
decorative door.
Hard wiring detail
1. Remove terminal cover plate from rear panel
of appliance.
2. Fit wires through hole in cover plate and make
connections to terminals.
3. Engage wires into plastic clip. Secure plastic clip with
two long silver screws (supplied in separate bag).
4. Replace cover plate onto rear panel.
Second active wire only
required (optional) for
multi-phase products
Plastic clips
Plastic clip
securing points
Cabinet construction for your appliance
For the best integration within a kitchen, install the
appliance in a standard 600mm wide cupboard that gives
a flush fit with the surrounding cupboard fronts as shown
in Fig. A. A recess of 20 mm is ideal.
With the exception of pyrolytic ovens, the appliance can
also be installed using a proud fit to the surrounding
cupboard as shown in Fig. B.
WARNING
CAUTION
For all Pyrolytic clean oven models, the oven must be
installed as a flush fit to the surrounding cupboards and
the “Infill panel” MUST not exceed 100mm in length. This
ensures a 16mm gap is maintained between the cabinet
and oven side to prevent the cupboard overheating.
Fig. A
Flush Fit
16mm
568mm
600mm
20mm
Infill
panel
Cupboard
door
Oven
100mm max
for Pyro
oven
Fig. B
Proud Fit
16mm
568mm
600mm
Infill
panel
Cupboard
door
Oven
100mm max
for Pyro oven
Levelling oven
Place a level in the oven as below, making sure the level
sits on the front and rear forms.
✓
INSTALLING YOUR APPLIANCE (CONTINUED)
Rated power input