INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE

Read the following electrical
connection details before
connecting electricity to range.

 

Before servicing, disconnect electrical

supply at circuit breaker, fuse or power cord.

Electric requirements:

A dedicated, properly grounded and polarized branch
circuit protected by a 15 amp. circuit breaker or time delay
fuse. 

See serial plate for proper voltage.

Extension cord precautions:

Because of potential safety hazards under certain
conditions, we strongly recommend against the use of any
extension cord. However, if you still choose to use an
extension cord, it is absolutely necessary that it be a 

UL

listed 3-wire grounding type 

appliance extension cord

and that the current carrying rating of the cord in amperes
be equivalent to or greater than the branch circuit rating.
Such extension cords are obtainable through your local
service organization.

 

 Please read carefully! 

 For personal

safety, this product must be properly grounded.

Do not, under any circumstances, cut or remove the third
(ground) prong from the power cord (See Fig. 12).

Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and obligation
of the customer to have it replaced with a properly
grounded three-prong wall receptacle.

Grounding instructions:

The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong grounding wall receptacle to minimize the
possibility of electric shock hazard from this appliance. The
customer should have the wall receptacle and circuit
checked by a qualified electrician to make sure the
receptacle is properly grounded and polarized.

Fig. 13

Burner cap lip

Burner cap

Correct burner cap placement

Fig. 14

Incorrect burner cap placement

Fig. 15

Check burner cap placement.

It is 

very important

 to be sure that all surface burner caps

and burner grates are properly installed and in the correct
locations 

before

 operating the appliance. Please note that

the burner heads are secured to the cooktop. 

The cooktop

is not removeable. 

Do not attempt to remove or lift the

cooktop.

 

 To prevent flare-ups and avoid creation of

harmful by-products, 

do not

 use the cooktop without all

burner caps properly installed to insure proper ignition and
gas flame size.

Always keep the burner caps and burner heads in place
whenever the surface burners are in use.

 Do not allow

spills, food, cleaning agents or any other material to
enter the gas orifice holder openings.

Check and be sure the size of each burner cap matches
the size of the burner head. Check and be sure that all

round

 style burner caps are correctly in place on round

burner heads.

Check and be sure that all 

oval 

style burner caps are

correctly in place on oval burner heads (if equipped).
Check and be sure that all 

dual 

or 

twin 

style burner caps

are correctly in place on dual or twin burner heads (if
equipped).

On round style burners, the burner cap lip (See Fig. 13)
should fit snug into the center of burner head and be level.
Refer to Figs. 14  & 15 for correct and incorrect burner cap
placement.

Once in place, you may check the fit by gently sliding the
burner cap from side to side (Fig. 16) to be sure it is
centered and firmly seated. When the burner cap lip makes
contact inside the center of the burner head you will be
able to hear the burner cap click. Please note that the
burner cap should NOT move off the center of the burner
head when sliding from side to side.

Fig. 16

Do not, under any
circumstances, cut,
remove or bypass the
grounding prong.

Preferred method

Grounding
type wall
receptacle

Power
supply
cord with
3-prong
grounding
plug

5

6

Fig. 12

Содержание FFGF3021ZW

Страница 1: ...ge Remove all packing material from the oven compartments before connecting the gas and electrical supply to the range Observe all governing codes and ordinances Be sure to leave these instructions with the consumer Important notes to the consumer Keep these instructions with your Use Care Guide for future reference Be sure your range is installed and grounded properly by a qualified installer or ...

Страница 2: ...ER FAILURE RESET ALL OVEN CONTROLS TO OFF IN THE EVENT OF A POWER FAILURE The electric ignitor will automatically re ignite the oven burner when power resumes if the oven thermostat control was left in the ON position When an electrical power failure occurs during use the surface burners will continue to operate During a power outage the surface burners can be lit with a match Hold a lighted match...

Страница 3: ...rials you will need Pipe joint sealant that resists action of LP Propane gas Fig h Gas line manual shut off valve Fig i A new flexible metal appliance conduit 1 2 NPT x 3 4 or 1 2 I D must be design certified by CSA International Because solid pipe restricts moving the range we recommend using a new flexible conduit 4 to 5 foot length for each new installation and additional reinstallations Fig j ...

Страница 4: ...in the wall or floor where the range is to be installed must be sealed 2 7 Recommended area for 120V outlet on rear of wall and area for thru the wall connection of pipe stub and shut off valve 18 Min to cabinets on either side of range 30 30 Min height from cooktop to cabinets 25 24 15 23 36 Std 30 11 1 2 Installation beside wall If installing beside a wall the minimum distance to combustible wal...

Страница 5: ...alled and does not allow the bracket to fit flush against wall remove molding or mount bracket to floor For wall mount Fig 4 locate the bracket by placing the back edge of the template against rear wall and the side edge of template on the mark made referencing the side of the range Place bracket on top of template and mark location of the screw holes in wall If rear of range is further than 1 1 4...

Страница 6: ...re regulator to LP Propane use Care must be taken during installation of range not to obstruct the flow of combustion and ventilation air For proper operation the maximum inlet pressure to the regulator should be no more than 14 inches of water column pressure The inlet pressure to the regulator must be at least 1 inch greater than regulator manifold pressure Example If regulator is set for natura...

Страница 7: ...east two 2 other top burners burning Be sure the gas supply inlet pressure is at least one inch above specified range manifold pressure The gas supply pressure should never be over 14 water column When properly adjusted for Natural Gas the manifold pressure is 4 For LP Propane Gas the manifold pressure is 10 c Tighten the gas supply fitting and or appliance conduit to flare union adaptor on the ri...

Страница 8: ...er cap placement Fig 14 Incorrect burner cap placement Fig 15 Check burner cap placement It is very important to be sure that all surface burner caps and burner grates are properly installed and in the correct locations before operating the appliance Please note that the burner heads are secured to the cooktop The cooktop is not removeable Do not attempt to remove or lift the cooktop To prevent fl...

Страница 9: ...to electric power a To check for proper ignition push in and turn a surface burner knob counterclockwise to the LITE position You will hear the igniter sparking b The surface burner should ignite when gas is available to the burner Purge air from supply lines by leaving knob in the LITE position until burner ignites Each burner should light within four 4 seconds in normal operation after air has b...

Страница 10: ... about your range always be sure to include the model and serial numbers and a lot number or letter from the identification plate on your range Your identification plate also tells you the rating of the burners the type of fuel and the pressure the range was adjusted for when it left the factory Adjust air shutter lower oven To determine if the oven burner flame is proper remove the oven bottom pa...