4
INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE
Installation with cabinets
Check location where the range will
be installed for proper electric and
gas supply, and stability of the floor.
The dimensions shown here must
be used and are minimal unless
otherwise stated. These
measurements do not allow for any
clearance below the cooking top or
at the rear of the range.
Contact surface must be solid and
level.
Things to remember:
•
Do not seal the range to side
cabinets.
•
Do not pinch the power supply
cord between the range and
rear wall.
•
If cabinet depth is greater than
25”, the oven front frame must
extend beyond cabinet front by
1/2” minimum (See Fig. 1).
•
All openings in the wall or floor
where the range is to be
installed must be sealed.
2”
7”
Recommended
area for 120V
outlet on rear of
wall and area for
thru the wall
connection of pipe
stub and shut-off
valve.
18”
Min. to cabinets on
either side of range
30”
30”
Min. height from
cooktop to cabinets
25”
24”
*15”
23”
36”
Std.
30”
11-1/2”
Installation beside wall
If installing beside a wall, the
minimum distance to combustible
wall on either side of range above
36" height should be according to
the BTU of the largest burner (See
Fig 2).
36±1/8”
(Adjustable)
46-5/8”
max
door
open
29-7/8”
25-3/4”
48-1/2”
max
30”
29-1/4”
max
door
closed
Fig. 1
Fig. 3
Fig. 2
10-1/2”
13”
Max.
Recommended area for thru
the floor connection of gas
pipe stub and shut-off valve.
* 9500 BTU or less
2"
10,000 - 16,999 BTU
3"
17,000 BTU or greater
5"
*
* Models without self-clean feature
may have an additional 7 inches