background image

GAS COOKTOP INSTALLATION INSTRUCTIONS

6

Assemble the flexible connector from the gas supply pipe 
to the pressure regulator in order: 1- manual shutoff 
valve, 2- ½" nipple, 3- ½" flare union adapter, 4- flexible 
connector, 5- ½" flare union adapter, 6- ½" nipple, 
pressure regulator.

Figure 6

To Appliance

To gas supply line

Shutoff Valve

All connections must be wrench-tightened

Figure 5

GAZ FLOW

Manual 

Shutoff 

Valve

Flare

Union

Flare

Union

Pressure

Regulator

Off

Flexible Connector

On

4. Provide an Adequate Gas Supply

This cooktop is designed to operate on natural gas at 4" 
(10.2 cm) of manifold pressure only.
A pressure regulator is connected in series with the 
manifold on the cooktop and must remain in series with 
the supply line.

For proper operation,

 the maximum inlet pressure to 

the regulator must be no more than 14" (35.6 cm) of 
water column (W.C.) pressure.
For checking the regulator, the inlet pressure must be at 
least 1" (2.5 cm) (or 2.5 kPa) greater than the regulator 
manifold pressure setting. The regulator is set for 4" 
(10.2 cm) of manifold pressure, the inlet pressure must 
be at least 5" (12.7 cm).
The gas supply line to the cooktop should be ½" (1.3 
cm) or ¾" (7.9 cm) pipe.

5. LP/Propane Gas Conversion

This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use with 
natural gas.
If you wish to convert your cooktop for use with LP/
Propane gas, use the supplied fixed orifices in the 
package containing the installation Instructions Manual, 
in a bag marked "FOR LP/PROPANE GAS CONVERSION". 
Follow the installation instructions packaged with the 
orifices.
The conversion must be performed by a qualified service 
technician in accordance with the manufacturer's 
instructions and all local codes and requirements of 
the authority having jurisdiction. Failure to follow 
instructions could result in serious injury or property 
damage. The qualified agency performing this work 
assumes responsibility for the conversion.

 Failure to make the appropriate conversion 

can result in personal injury and property damage.

Important: 

Remove all packing material and literature 

from cooktop before connecting gas and electrical 
supply to cooktop.

6. Install Pressure Regulator

Install the pressure regulator with the arrow on the 
regulator pointing up toward the unit in a position 
where you can reach the access cap.

 

FIRE HAZARD.

 Do not make the 

connection too tight. The regulator is die cast. 
Overtightening may crack the regulator resulting in a gas 
leak and possible fire or explosion.

Use pipe-joint compound made for use with Natural and 
LP/Propane gas to seal all gas connections. If flexible 
connectors are used, be certain connectors are not 
kinked.
The supply line should be equipped with an approved 
shutoff valve. This valve should be located in the same 
room as the cooktop and should be in a location that 
allows ease of opening and closing. Do not block access 
to the shutoff valve. The valve is for turning on or 
shutting off gas to the appliance.

Open the shutoff valve in the gas supply line. Wait a few 
minutes for gas to move through the gas line.

Check for leaks. 

Leak testing of the appliance shall be 

conducted according to the manufacturer's instructions. 
After connecting the cooktop to the gas supply, check 
the system for leaks with a manometer. If a manometer 
is not available, turn on the gas supply and use a liquid 
leak detector (or soap and water) at all joints and 
connections to check for leaks.

 Do not use a flame to check for leaks from 

gas connections. Checking for leaks with a flame may 
result in a fire or explosion.

Tighten all connections

 if necessary to prevent gas 

leakage in the cooktop or supply line.

Содержание FFGC3015L W

Страница 1: ...cabinet 24 min for protected surface A B C D E F 30 Min 76 2 cm Min G H All dimensions are in inches cm Dimension F is for clearance under cooktop for gas connection NOTE Wiring diagram for this appliances is enclosed in this booklet Only some models are available in Canada P N 318201489 1102 Rev C English pages 1 8 Español páginas 9 15 Français pages 16 23 Wiring Diagram pages 23 24 Printed in Ca...

Страница 2: ...p is installed and grounded properly by a qualified installer or service technician This cooktop must be electrically grounded in accordance with local codes or in their absence with the National Electrical Code ANSI NFPA No 70 latest edition in the United States or in Canada with the Canadian Electrical Code CSA C22 1 Part 1 The burners can be lit manually during an electrical power outage To lig...

Страница 3: ...the Cooking Platform and Unprotected Wood or Metal Cabinet 24 61 cm Min when Bottom of Wood or Metal Cabinet is Protected by Not Less Than 1 8 Flame Retardant Millboard Covered with Not Less Than N0 28 MSG Sheet Steel 0 015 0 04 cm Stainless Steel 0 024 0 06 cm Aluminum or 0 020 0 05 cm Copper 24 61 cm 13 33 cm Max Depth For Cabinet Installed Above Cooktop Dimension L is the Minimum Clearance Requ...

Страница 4: ...G F H 36 Min 91 4 cm Min Use 3 4 1 9 cm plywood installed on two runners flush with toe plate Base must be capable of supporting 150 pounds 68 kg for 27 models and 200 pounds 90 kg for 30 models Cut an opening in wood base minimum 9 x 9 23 X 23 cm 2 5 cm from left side filler panel to route armoured cable to junction box If no cooktop is installed directly over the oven unit 5 12 7 cm maximum is a...

Страница 5: ... not available have one installed by a qualified technician 1 Wall Outlet Location 2 Installation Insert the cooktop into the countertop opening Note After inserting the cooktop into the countertop opening make sure the unit is sitting on the metal flange around the top of the burner box Cooktop must not sit on the porcelain top Avoid cutting an oversized hole in the countertop 3 Clamp Down Inform...

Страница 6: ...uirements of the authority having jurisdiction Failure to follow instructions could result in serious injury or property damage The qualified agency performing this work assumes responsibility for the conversion Failure to make the appropriate conversion can result in personal injury and property damage Important Remove all packing material and literature from cooktop before connecting gas and ele...

Страница 7: ...ed by a qualified electrician to make sure the receptacle is properly grounded Where a standard 2 prong wall receptacle is installed it is the personal responsibility and obligation of the consumer to have it replaced by a properly grounded 3 prong wall receptacle Do not under any circumstances cut or remove the third ground prong from the power cord Disconnect electrical supply cord from wall rec...

Страница 8: ...te Make sure all controls are left in the OFF position Make sure the flow of combustion and ventilation air to the cooktop is unobstructed Model and Serial Number Location The serial plate is located on the underside of the cooktop When ordering parts for or making inquires about your range always be sure to include the model and serial numbers and a lot number or letter from the serial plate of y...

Страница 9: ...de forma de T se debe instalar en la línea del suministro de gas de este aparato Refierase a su placa de serie para la certificación de la agencia aplicable Impreso en Canada Todas las dimensiones se dan en pulgadas cm La dimensión F esté por debajo de la plancha de cocinar para la conexión de la línea de suministro de gas NOTA Se adjunta los diagramas de cables de esta plancha de cocinar con el l...

Страница 10: ...rectamente por un instalador o técnico calificado La plancha de cocinar debe conectarse eléctricamente a tierra de acuerdo con los códigos locales o de no existir con el código eléctrico ANSI NFPA No 70 última edición en los Estados Unidos or in Canada con el Canadian Electrical Code CSA C22 1 Parte 1 Los quemadores pueden encenderse manualmente durante una interrupción del suministro eléctrico Pa...

Страница 11: ...61 cm 13 33 cm Max Depth For Cabinet Installed Above Cooktop Dimensiones L este espacio mínimo desde el borde de la plancha de cocinar y el almacenamiento de combustible Dimensiones J este espacio mínimo desde el borde de la plancha de cocinar y el almacenamiento de combustible No es posible utilizar cajones con esta plancha de cocinar porqué la caja de empalme se extiende de 3 7 6 cm por encima d...

Страница 12: ...ión del horno de pared éste debe a s e g u r a r s e a l o s gabinetes mediante soportes de montaje 4 1 2 Max 11 5 cm Instale contrachapado de 3 4 1 9 cm sobre dos correderas nivelado con la parrilla inferior La base debe poder sostener 150 libras 68 kg para los modelos 27 y 200 libras 90 kg para los modelos 30 Corte una abertura de 9 X 9 23 cm X 23 cm mínimo en el fondo del contrachapado a 2 5 cm...

Страница 13: ... soportado por la base metálica que rodea la parte superior de la caja del quemador La plancha de cocinar no debe apoyarse contra la parte superior Evite cortar un agujero demasiado grande en el mostrador 3 Información para sujetar el aparato Una vez que el aparato está instalado en la apertura del mostrador se tiene que sujetar como se indica Para ajustar el aparato inserte la consola de escuadra...

Страница 14: ...sión Apagado Off Conector flexible Abierto On Abra la válvula de cierre en el tubo de suministro de gas Espere unos minutos para que el gas pase a través del tubo de gas Figura 6 Al artefacto A la linea de gas Válvula de cierre La línea de suministro de gas por el plancha de cocinar debería tener un tubo de 1 3 cm o de 1 9 cm 5 Conversión de gas propano licuado Esta plancha de cocinar ha sido dise...

Страница 15: ...F d Retire la perilla del quemador de superficie e Inserte un destornillador fino aplanado en el orifico del vásta go de la válvula e inserte en el tornillo ranurado El tamaño de la llama puede aumentarse o disminuirse dándole vuelta al tornillo Dé vuelta en sentido opuesto a las manecillas del reloj para aumentar el tamaño de la llama Dé vuelta en sentido a las manecillas del reloj para disminuir...

Страница 16: ...e le fournisseur vous donnera S il vous est impossible de rejoindre votre distributeur de gaz communiquez avec le service d incendie L installation et l entretien doivent être effectués par un installateur qualifié un service d entretien ou de réparation accrédité ou le distributeur de gaz Imprimé au Canada UN INSTALLATEUR QUALIFIÉ DOIT EFFECTUER L INSTALLATION ET LE SERVICE IMPORTANT CONSERVEZ CE...

Страница 17: ... d entretien qualifié Le circuit électrique de cette plaque de cuisson doit être mis à la terre conformément aux règlements locaux ou en leur absence au code national de l électricité ANSI NFPA no 70 dernière édition aux Etats Unis ou à la norme canadienne d électricité ACNOR C22 1 partie 1 au canada Lors d une panne de courant électrique les brûleurs de surface peuvent être allumés manuellement p...

Страница 18: ... 1 8 0 3 cm recouvert d une feuille de métal MSG No 28 d acier inoxydable d un minimum de 0 015 0 04 cm d aluminimu de 0 024 0 06 cm ou de cuivre de 0 020 0 05 cm 24 61 cm L armoire supérieure ne doit pas excéder une profondeur de 13 33 cm La dimension L est la distance minimum requise du rebord de la plaque de cuisson au mur en matériel inflammable le plus proche du côté droit de l appareil La di...

Страница 19: ...du câble armé de l appareil vers la boîte de jonction Si aucune table de cuisson n est directement installée par dessus l unité du four le maximum permis au dessus du plancher est de 5 12 7 cm 208 240 Volt boîte de jonction pour le four encastré Approx 3 7 5 cm Il faut fermer les côtés de l habi tacle par des panneaux de bois pour isoler l appareil des armoires de chaque côté La hauteur de ces pan...

Страница 20: ...ible demandez à un électricien qualifié d en installer une 1 Emplacement de la prise de courant murale Comptoir Support de retenu Vis Figure 4 Plaque de cuisson 12 30 5 cm 8 20 3 cm 10 25 4 cm CL de l appareil L emplacement recommandé pour la prise de courant de 120V avec contact de mise à la terre se trouve sur le mur arrière CL de l appareil 22 55 9 cm Figure 3 3 Instructions de fixation Une foi...

Страница 21: ...t emballés dans un sac marqué POUR CONVERSION AU GAZ PROPANE ce sac se trouve dans l enveloppe documents contenant le feuillet Instructions d installation Suivre les instructions d installation se trouvant dans l enveloppe qui contient les orifices Un installateur qualifié doit effectuer l installation et le service conformément aux instructions du fabricant et à tous les codes et règlements appli...

Страница 22: ...rre du cordon d alimentation Débranchez le cordon d alimentation électrique de la prise de courant murale avant de réparer ou de nettoyer la plaque de cuisson 8 Vérification de fonctionnement Référez vous au Guide de l utilisateur fourni avec votre appareil pour le mode de fonctionnement et l entretien de votre plaque de cuisson 1 Retirez le matériau d embalalge des brûleurs 2 Branchez l alimentat...

Страница 23: ...ue de cuisson Avant d appeler le service d entretien Consultez la liste des vérifications préventives et les instructions d opération dans votre Guide de l utilisateur Vous sauverez probablement du temps et de l argent La liste contient les incidents ordinaires ne résultant pas de défectuosités dans le matériel ou la fabrication de cet appareil Pour obtenir nos adresse et numéro de téléphone référ...

Страница 24: ...WIRING DIAGRAM SCHÉMA DE CÂBLAGE DIAGRAMA DE LA INSTALACIÓN ALÁMBRICA 36 Gas Cooktop Plancha de cocinar a gas modelos de 36 pulgadas Table de cuisson à gaz 36 ...

Отзывы: