ROOM AIR CONDITIONERS TROUBLESHOOTING

CAUTION:  Review Safe Servicing Practices in
the front of this manual before attempting
diagnostic procedures and repairs.

AIR CONDITIONER VOLTAGE LIMITS

E

T

A

L

P

E

M

A

N

G

N

I

T

A

R

M

U

M

I

N

I

M

M

U

M

I

X

A

M

C

A

V

5

1

1

C

A

V

5

.

3

0

1

C

A

V

5

.

6

2

1

C

A

V

0

3

2

C

A

V

7

0

2

C

A

V

3

5

2

0

3

2

/

8

0

2

C

A

V

5

.

7

9

1

C

A

V

3

5

2

AIR CONDITIONER VOLTAGE LIMITS

Low voltage is a common cause of trouble in the operation
of any room air conditioner.

Improper voltage may cause one or more of the following
problems:
1. Unit will not start.
2. Compressor motor cycling on motor protector.
3. Premature failure of motor protector.
4. Blown fuses.
5. Premature failure of compressor or fan motor.
6. Noticable dimming of lights when air conditioner is

running.

7. Evaporator icing. Low voltage may reduce fan speed

resulting in inadequate air flow over evaporator, thereby
allowing it to ice up.

HIGH VOLTAGE

High voltage can be equally troublesome, causing motors
to overheat, cycle on their protectors, or break down
electrically. This problem can only be solved by the power
company.

ELECTRONIC CONTROL

This  control is not repairable. If any component in the
control is defective, the entire control must be replaced.

IMPORTANT NOTICE:

  Repair or replace any

malfunctioning line voltage component before testing
or replacing the electronic control. 

DO NOT

 assume a

service problem is directly caused by the electronic
control system. A line voltage component (including
power cord and wiring) that has opened, shorted,
grounded or otherwise malfunctioned, may have created
a service problem.

Low voltage can also be the direct result of inadequately
wired circuits, extension cords, or loose fuses and
connections to the power supply. Voltage may also be a
general condition in the area (a responsibility of the power
company).

All units will start and run on the minimum voltage stated
in the chart to the left, and will perform satisfactorily if the
voltage remains constant. Low voltage caused by defective
wiring will not remain constant under load.

To test for low voltage, use a reliable meter with sufficient
capacity to measure the required voltage. Take
measurements at the electric power entry point and at the
electric outlet serving the air conditioner. Take readings
with the unit off, while the unit is starting, and again while
the unit is running. The lowest reading should not drop
below the lowest value listed in the chart.

SYMPTON

POSSIBLE CAUSE

Fan motor will not run.

1. No power.
2. Power supply cord.
3. Selector switch.
4. Energy saving switch (if applicable).
5. Electronic control (if applicable).
6. Wire disconnected or connection loose.
7. Capacitor. (Discharge capacitor before testing.)
8. Defective fan motor windings.
9. Will not rotate. Fan blade hitting shroud or blower

wheel hitting scroll. (Motor cycles on overload.)

Fan motor runs intermittently.

1. Cycle on motor protector.

Содержание FAH085N1T

Страница 1: ...and visit the Frigidaire Web Site at User name service Password tips http www frigidaire com Safe Servicing Practices 3 Model Specifications 4 7 Compressor Overloads 8 Restrictor Tube Data 8 Receptacle Codes 9 Product Dimensions 10 Thermostat Diagrams 11 12 Fan Blower Diagrams 13 14 Wiring Diagrams 15 17 Troubleshooting 18 20 ...

Страница 2: ...Electronic Control 11 CompactRotary 11 IntermediateTopControl Rotary 11 2004 Heavy Duty Thermostat Locations 12 2004 Builder Thermostat Locations 12 2004 Slider Thermostat Locations 12 Fan and Blower Location Diagrams 13 14 Compact 13 18 5 No Side Louvers 13 Slider Casement 13 Motor 14 HeavyDutyTopControl 14 Heavy Duty Side Discharge 14 Wiring Diagrams 15 17 A232012 15 309201101 02 16 309201102 02...

Страница 3: ...fgassupply Turnoffwatersupply 3 Never interfere with the proper operation of any safety device 4 Use only OEM replacement parts cataloged for this appliance Substitutions may defeat compliance with safety standards set for home appliances 5 GROUNDING The standard color coding for safety ground wires is GREEN or GREENwithYELLOWSTRIPES DONOTusegroundleadsascurrentcarrying conductors ItisEXTREMELYimp...

Страница 4: ... Motor Number RPM CMP EVAP High Medium Low Heat Only 10 370 Heshan 309630615 980 530 810 400 6 440 Heshan 309630613 975 500 775 400 6 450 Heshan 309630613 1000 480 800 380 6 450 Heshan 309630613 1000 480 800 380 7 5 450 Heshan 309630614 1115 550 925 470 Refrigeration System Compressor Mfg Compressor Number Compressor Type Overload Protector Capacitor µ farads Refrigerant Charge Restrictor Tube The...

Страница 5: ...an 309630616 1145 590 925 470 7 5 450 Heshan 309630616 1145 570 960 475 10 370 Welling 309647503 1130 280 950 230 800 190 10 370 Welling 309647503 1130 280 950 230 800 190 10 370 Welling 309647503 1130 280 950 240 800 210 Refrigeration System Compressor Mfg Compressor Number Compressor Type Overload Protector Capacitor µ farads Refrigerant Charge Restrictor Tube Thermostat Type LG QP348KBB Rotary ...

Страница 6: ...Medium Low Heat Only 6 450 Welling 309647501 1130 280 1010 240 880 210 6 450 Welling 309647501 1130 280 1010 240 880 210 7 5 450 Welling 309647502 1280 300 1130 260 975 230 7 5 450 Welling 309647502 1280 300 1130 260 975 230 5 370 Heshan 309646002 1120 240 1000 210 940 190 Refrigeration System Compressor Mfg Compressor Number Compressor Type Overload Protector Capacitor µ farads Refrigerant Charge...

Страница 7: ... Fan Motor Mfg Fan Motor Number RPM CMP EVAP High Medium Low Heat Only 15 370 Heshan 309646001 1400 305 1230 260 1050 210 15 370 Heshan 309646001 1400 305 1230 260 1050 210 Refrigeration System Compressor Mfg Compressor Number Compressor Type Overload Protector Capacitor µ farads Refrigerant Charge Restrictor Tube Thermostat Type LG QK134CCA Rotary A363785 50 370 20 46 A112137 Bulb LG QK164CCA Rot...

Страница 8: ... 097 0 046 25 0 261 0 283 A112145 Black 37 00 0 099 0 049 20 0 288 0 312 A112119 Black 35 00 0 099 0 049 20 0 296 0 320 I D PSIG CFM Dry Air Restrictor Tube Data Style Internal Diameter Color Code Length O D Test Amp Opening Time Sec 309260303 2R11S3R126A6A MRA98705 A363785 QK134CCA MRA12061 12056 150 61 50 5 6 16 A363785 QK141CCA MRA12061 12056 150 61 50 5 6 16 A363776 QK164CCA MRA12053 12057 150...

Страница 9: ...ptacle Power Supply Cord with 3 prong Grounding Plug Code A 115 Volts 15 Amps NEMA 5 15 TYPE Code B 115 Volts 20 Amps Code C 230 Volts 15 Amps NEMA 6 20 TYPE Code D 230 Volts 20 Amps NEMA 6 20 TYPE Code E 230 Volts 30 Amps NEMA 6 30 TYPE NEMA 5 20 TYPE ...

Страница 10: ...10 Product Dimensions Heavy Duty Slide Out Top Control ...

Страница 11: ...11 Control Thermostat Location Diagrams Slider Casement Intermediate Rotary Top Control Compact Rotary Control Compact Electronic Control ...

Страница 12: ...tor holder Place between 9th 10th rows up from the bottom 15 1K 18K 22 K 18 5K 28 5K 25K Freeze thermistor and freeze thermistor holder 2004 Heavy Duty Thermostat Locations 2004 Builder Thermostat Locations 7 87 Freeze thermistor and freeze thermistor holder Section B B 8K and 10K 12K 3 94 B A Section A A Bracket Evap B A fin first row from bottom second row from bottom third row from bottom fourt...

Страница 13: ...13 Fan and Blower Location Diagrams Slider Casement Compact 18 5 No Side Louvers ...

Страница 14: ...ER WHEEL SHROUD SEAL ASSY TORQUE TO 22 27 IN LBS OF FLAT COND FAN SLINGER RING SHROUD 560 370 REF 380 SCREW 3 SHROUD BULKHEAD ASSY CLAMP COND FAN CLAMP SCREW FAN CLAMP BULKHEAD ASSY BLOWER WHEEL To be fully seated against motor shaft bottom out on shaft Clamp Clamp Evaporator Side Condenser Side CONDENSER FAN To be fully seated against motor shaft bottom out on shaft Motor Shaft Motor ...

Страница 15: ...STAT THERMOSTAT DE LA PIÉCE COMPRESSOR OVERLOAD SURCHARGE DU COMPRESSEUR FAN MOTOR MOTEUR DU VENTILATEUR COMPRESSOR COMPRESSEUR BK C R S W R W COMPRESSOR CAPACITOR CONDENSATEUR DU COMPRESSEUR START ASSIST DÉMARREUR FAN CAPACITOR CONDENSATEUR DU VENTILATEUR BR ALTERNATE INTERNAL COMPRESSOR OVERLOAD AUTRE SURCHARGE INTERNE DU COMPRESSEUR BK W R R S C RIBBED BLUE RAYE BLEU GND TERRE G COLOR CODE BL B...

Страница 16: ...FL AC N N1 N2 0 Heater Chauffage Electrique OR Heater Relay Relais Du Chauffage Electrique BK OR 1 8 6 4 R R 2 BK Black Noir BL Blue Bleu BR Brown Brun G Green Vert OR Orange Orange R Red Rouge W White Blanc Y Yellow Jaune 309201102 02 Relay Relais Relay Relais Relay Relais DAHT Sonde Du Chauffage Electrique Relay Relais LO R OR Fan motor Moteur Du Ventilateur R S R W Compressor capacitor Condensa...

Страница 17: ...D Ambiance Evap Sensor Sonde Anti Givre Compressor Compresseur Fan motor Moteur Du Ventilateur Compressor capacitor Condensateur Du Compresseur C S W R R BK Fan motor capacitor Condensateur Du Ventilateur S W C Connector Connecteur Compressor Overload Surcharge Du Compresseur R R BR G Vert GND BK N Compressor Relay Relais Du Compresseur 3 4 BK R Ionizer Ion Optional Facultatif G Vert GND Ribbed Bl...

Страница 18: ... the electronic control DO NOT assume a service problem is directly caused by the electronic control system A line voltage component including power cord and wiring that has opened shorted groundedorotherwisemalfunctioned mayhavecreated a service problem Low voltage can also be the direct result of inadequately wired circuits extension cords or loose fuses and connections to the power supply Volta...

Страница 19: ...motor 5 Condenser air flow restriction 6 Condenser fins damanged 7 Capacitor 8 Wiring 9 Refrigerant system Insufficient cooling 1 Low capacity 2 Air filter 3 Exhaust door open 4 Unit undersized Excessive noise 1 Evaporator blower wheel 2 Condenser wheel 3 Copper tubing 4 Compressor internal noise 5 Fan motor Excessive water or condensation 1 Unit operating under extremely high humidity conditions ...

Страница 20: ... outside temperature No heat 1 No power 2 Selector switch position 3 Temperature control position 4 Fan motor 5 Heating element 6 Selector switch 7 Temperature control 8 Terminals and connectors Fan motor will not rotate during heat cycle 1 Thermostatic drain valve Water level control if Heat Cool models only applicable ...