Air Conditioner Features

TO OPERATE ON FAN ONLY:

TO USE THE
ENERGY SAVER FEATURE:

TIMER: DELAY START/STOP FEATURE:

YOU WILL SEE:

YOU WILL SEE:

YOU WILL SEE

 HOW MUCH TIME IS CHOSEN:

DO THIS:

LIGHT On

LIGHT On

LIGHT On

PRESS

MODE BUTTON

CHOOSE

FAN ONLY

(continued)

DO THIS:

PRESS

MODE BUTTON

CHOOSE

ENERGY SAVER

FIRST

DO THIS:

PRESS

TIMER BUTTON

THEN

DO THIS:

PRESS

TEMP/TIMER

SET BUTTON

Note: 

Use this function only when cooling is not desired, such as for room air circulation or to exhaust stale air. (Remember to open the

Note:

In this mode, the fan will continue to run for another 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes

Note 1:

For Delay Stop, the unit must be in the On position.

Note 2:

For Delay Start, the unit must be in the Off position.

First, PRESS TIME BUTTON
Then to adjust timer setting, tap or hold the UP arrow (      ) or the DOWN arrow (      ) to change delay timer at. 5 hour increments, up to 10
hours, then by 1 hour increments up to 24 hours. The control will count down the time remaining until start (8, 7.5, 7, etc.). The Delay Start
mode automatically selects cooling with maximum Fan Speed. The temperature maintained will be the same as previously set. To change the
set temperature, press "COOL" then Up or Down arrows until the desired temperature is indicated on the display. After 5 seconds, the con-
trol will automatically change the display back to the hours remaining until the unit will start/stop. PRESSING the unit On/Off button at any
time will cancel the Delay Start/Stop function. The Delay Start/Stop Feature will work until the unit either starts or stops. Once that happens
he above steps have to be repeated again.

at 10 minute intervals until the room temperature is above the set temperature, at which time the the cooling system turns back on. 

vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You can choose any fan speed you prefer. (Exc-

ept "Auto Temp").
During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode.

Fan Only cannot be selected when the unit is in the 'Remote Sensing' Mode. (On those units with that feature).

Содержание 66121617

Страница 1: ...E CARE MANUAL provides specific operating instructions for your model Use the room air conditioner only as instructed in this USE CARE MANUAL instructions are not meant to cover every possible condition and situation that may occur Common sense and caution must be practiced when installing operating and maintaining any appliance USE CARE MANUAL READ AND SAVE THESE INSTRUCTIONS P N 66121617 MEDIANa...

Страница 2: ...icers or external causes such as abuse misuse inadequate power supply or acts of God 4 Products with original serial numbers that have been removed or altered and cannot be readily determined Keep your bill of sale delivery slip or some other appropriate payment record The date on the bill establishes the warranty period should service be required If service is performed it is in your best interes...

Страница 3: ...t installation High Pitched Chatter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Swishing Droplets of water hitti...

Страница 4: ... is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with out...

Страница 5: ...h the remote TOUCH PAD AUTO TEMP DISPLAYS TEMPERATURE TIME FAN SPEED SETS MODE TURNS UNIT ON OR OFF SETS FAN SPEED ADJUSTS TEMP TIME ACTIVATES TIMER FEATURE CHECK FILTER RESET BUTTON CLEAN AIR FEATURE some models SLEEP MODE ADJUSTS TEMP TIME SETS SETS ON OFF LIGHT FAN SPEED SETS MODE ACTIVATE TIMER AUTO TEMP REMOTE CONTROL FOR HEAT MODELS Fig A ON OFF LIGHT FAN SPEED SETS MODE ACTIVATE TIMER AUTO ...

Страница 6: ...t speed as the room returns to the original set temperature cally maintained anywhere between 60o F 16o C and 90o F 32o C for cooling mode The temperature will be automatically maintained anywh Press the Fan Faster button will increase the fan speed from Low LO to Medium ME to High HI The digital display will indicate your chosen speed Press the Fan Slower button will decrease the fan speed from H...

Страница 7: ...ol will count down the time remaining until start 8 7 5 7 etc The Delay Start mode automatically selects cooling with maximum Fan Speed The temperature maintained will be the same as previously set To change the set temperature press COOL then Up or Down arrows until the desired temperature is indicated on the display After 5 seconds the con trol will automatically change the display back to the h...

Страница 8: ...ollen and impurities from the air To cancel this feature Note In this MODE the set temperature will increase by 2 degrees F 30 minutes after the mode is selected The temperature will then increase by another 2 degrees F after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the or iginally selected temperature This ends the Sleep MODE and the unit w...

Страница 9: ...et temperature will only be displayed on the unit itself The LIGHT on the unit control will pulse to indicate it received the signal The LIGHT on the remote control will pulse each time it sends a signal It will con tinue to send this signal until the feature is deactivated by pressing the remote sensing button If the unit does not receive the remote sensing signal during any 3 minute interval the...

Страница 10: ...ttons together for 3 seconds Fresh Air Vent Control On some models The Fresh Air Vent allows the air conditioner to 1 Recirculate inside air Vent Closed see Fig 1 2 Draw fresh air into the room Vent Open see Fig 2 3 Exchange air from the room and draws fresh air into the room Vent and Exhaust Open see Fig 3 Fig 1 OFF Fig 2 FRESH AIR Fig 3 VENT AUGER WHEEL The louvers will allow you to direct the a...

Страница 11: ...ing around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air conditioner during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton Care and Cleaning Energy Saving Ideas Do not block air flow in...

Страница 12: ...defrost set to FAN ONLY Mode Temperature is set too Low for night time cooling To defrost the coil set to FAN ONLY Mode Then set Tem perature to a Higher setting Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too High Set temperature to a Lower setting Air directional louvers positioned improperly Position louvers for better air distribution ...

Отзывы: