background image

4

C. Level and Position Range

 - Level range by adjusting the

(4) leveling legs with a wrench. Note: A minimum clearance
of 1/8" is required between the bottom of the range and the
leveling leg to allow room for the bracket.  Use a spirit level
to check your adjustments.  Slide range back into position.
Visually check that rear leveling leg is inserted into and
fully secured by the Anti-Tip Bracket by removing lower
panel or storage drawer. For models with a warmer drawer
or broiler compartment, grasp the top rear edge of the
range and carefully attempt to tilt it forward.

2. Provide an adequate gas supply.

This unit is pre-set to operate on 4" natural gas manifold
pressure. A convertible pressure regulator is connected to the
manifold and MUST be connected in series with the gas supply
line. If the LP/Propane conversion kit has been used, follow
instructions provided with the kit for converting the pressure
regulator to LP/Propane use. The LP kit can be found on the
back side of the range (some models).

Care must be taken during installation of range not to obstruct
the flow of combustion and ventilation air.

For proper operation

, the maximum inlet pressure to the

regulator should be no more than 14 inches of water column
pressure. The inlet pressure to the regulator must be at least
1 inch greater than regulator manifold pressure. Examples: If
regulator is set for natural gas 4 inch manifold pressure, inlet
pressure must be at least 5 inches; if regulator has been
converted for LP/Propane gas 10 inch manifold pressure, inlet
pressure must be at least 11 inches.

Leak testing of the appliance shall be conducted according to
the instructions in step 4g.

The gas supply line should be 1/2" or 3/4" I.D.

3. Seal wall openings.

Seal any openings in the wall behind the range and in the floor
under the range after gas supply line is installed.

Fig. 4a

Fig. 4b

Fig. 4c

Wall

Edge

23"

15"

2"

7"

11-1/2"

10-1/2"

Recommended area for

120V outlet on rear of

wall and area for thru

the wall connection of
pipe stub and shut-off

valve is shaded area.

Recommended area for thru

the floor connection of

pipe stub and shut-off valve.

Centerline

of range

Centerline

of range

CL

4.

Connect the range to the gas supply.

NOTE: To prevent leaks use pipe joint sealant on all male
(outside) pipe threads.

*Please note:
Models without
self-cleaning
feature may
have an
additional 4 to
7 inches
clearance from
the floor.

*

30" GAS RANGE INSTALLATION INSTRUCTIONS

(For Models with Sealed Top Burners)

Содержание 316259359

Страница 1: ...jury or death FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach you...

Страница 2: ...llappliances Neverleave the oven door open when the range is unattended Stepping leaning or sitting on the doors ordrawersofthisrangecanresultinseriousinjuriesand can also cause damage to the range Do not store items of interest to children in the cabinets above the range Children could be seriously burned climbing on the range to reach items To eliminate the need to reach over the surface burners...

Страница 3: ...rovided for installation in wood or cement fastened to either the floor or wall When installed to the wall make sure that screws completely penetrate dry wall and are secured in wood or metal When fastening to the floor or wall be sure that screws do not penetrate electrical wiring or plumbing A LocatetheBracketUsingtheTemplate Bracketmay belocatedoneithertheleftorrightsideoftherange Use the infor...

Страница 4: ...essure to the regulator should be no more than 14 inches of water column pressure The inlet pressure to the regulator must be at least 1 inch greater than regulator manifold pressure Examples If regulator is set for natural gas 4 inch manifold pressure inlet pressure must be at least 5 inches if regulator has been convertedforLP Propanegas10inchmanifoldpressure inlet pressure must be at least 11 i...

Страница 5: ...ure is 4 For LP Propane Gas the manifold pressure is 10 DO NOT allow regulator to turn on pipe when tightening fittings a Installanexternalmanualgasshut offvalvetogassupply lineinanaccessiblelocationoutsideoftherange Besure you know where and how to shut off the gas supply to the range b Install1 2 flareunionadaptertopressureregulatorusing NO MORE THAN 15ft lbs of torque NOTE Be sure to stabilize ...

Страница 6: ...connection details first then connect electricity to range Before servicing disconnect electrical supply at circuit breaker fuse or power cord Electric Requirements A dedicated properly grounded and polarizedbranchcircuitprotectedbya15amp circuitbreaker or time delay fuse See serial plate for proper voltage Extension Cord Precautions Becauseofpotentialsafetyhazardsundercertainconditions we strongl...

Страница 7: ...ff Adjust flame until you can quickly turn knob from LITE to LOWEST POSITION without extinguishing the flame Flame should be as small as possible without going out Note Air mixture adjustment is not required on surface burners Test to verify if LOW setting should be adjusted a Push in and turn control to LITE until burner ignites b Push in and quickly turn knob to LOWEST POSITION c If burner goes ...

Страница 8: ... Youridentificationplatealsotellsyoutheratingoftheburners the type of fuel and the pressure the range was adjusted for when it left the factory 11 Air Shutter Broil Burner The approximate flame length of the broil burner is 1 inch distinct inner blue flame To determine if the broil burner flame is proper set the oven to broil Iftheflameisyellowincolor increaseairshutteropeningsize See 2 in illustr...