background image

10

Air Conditioner Feature s

(continued)

ADDITIONAL THINGS YOU SHOULD KNOW

Now that you have mastered the operating procedure, here are more features in your control that you should become familiar
with.

• Remote control works exactly like the control panel,  follow the same instructions.

• The “Cool “ circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents

overheating of the compressor and possible circuit breaker tripping. The fan will continue to run during this time.

• The control will maintain the set temperature within 2-3 degrees Fahrenheit, between 60F and 90F degrees.

Fresh Air Vent Control

The Fresh Air Vent allows the air conditioner to recirculate inside air (OFF), draw
air into the room (FRESH AIR) or exhaust stale air to the outside (VENT). See Figures
1, 2 & 3 for this operation.
• The “OFF” position is used when 

MAXIMUM 

cooling is desired. It may also be

for room air re-circulation without cooling when the selector switch is set to the
FAN position, this will also filter the room air.

• The FRESH AIR position allows outside air to be drawn into the room to refresh

the inside room air.

• The VENT position removes stale air from the room and exhausts it to the

outside.

• Any vent position can be used with any fan selection.

Figure 1 (OFF)

Figure 2 (FRESH AIR)

Figure 3 (VENT)

Содержание 309000834

Страница 1: ...OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS AIR CONDITIONER ELECTRONIC CONTROL P N 309000834 10 99 ...

Страница 2: ... to a grounded power supply of sufficient voltage replacement of blown fuses repair of loose connections or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs and or fluorescent...

Страница 3: ...ioner Features 11 Care and Cleaning 12 Avoid Service Checklist 1996 White Consolidated Industries Inc All rights reserved NOTE This Owner s Guide provides specific operating instructions for your model Use the room air conditioner only as instructed in this Owner s Guide These instructions are not meant to cover every possible condition and situation that may occur Common sense and caution must be...

Страница 4: ...against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with outside protective cover in place This could result in mechanical damage within the air condi...

Страница 5: ...ditioner included in a decorative kit To assemble follow these steps Before installation remove the tilt panel from the frame Grasping the panel from both sides gently pull to release then lift panel from pivot points at bottom of frame STEP 1 INSTALL DECORATIVE FRONT TO CABINET Decorative Front Loosen the screw to the left of the Electronic Control by 1 2 turn to easily install the decorative fro...

Страница 6: ...ze yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functions you desire The unit can be controlled by the touch pad alone or with the remote Slip battery cover off and pull the piece of plastic from between the battery end and the connector For some applications the batteries supplied will first need to be installed Note Remember that ...

Страница 7: ...eds will readjust back to LO as the room returns to the original set temperature 7 Note Tap or hold either up or down v button until the desired temperature is seen on the screen This temperature will be automatically maintained anywhere between 60F 15C and 90F 32C If you want the display to read the actual room temperature see step 5 Air Conditioner Features continued DO THIS PRESS TO RAISE PRESS...

Страница 8: ...t running PRESS FAN ONLY CHOOSE ONE DO THIS PRESS ENERGY SAVER YOU WILL SEE STEP 6 TO USE THE ENERGY SAVER FEATURE Note In this mode when the compressor shuts off the fan will continue to run for another 3 minutes then shut off until cooling is needed as sensed by the room temperature control During this time it may come on for 3 minutes to sense whether cooling is needed then it will go off for 1...

Страница 9: ... Up or Down arrows until the desired temperature is indicated on the display Press Timer pad again to show remaining time Switching unit on at any time will nullify this setting DO THIS PRESS if unit is not running PRESS YOU WILL SEE STEP 9 TO SET FOR DELAYED STOP Note The unit must be running to make this setting Proceed as in step 8 to change the desired number of hours The display will then con...

Страница 10: ...ture within 2 3 degrees Fahrenheit between 60F and 90F degrees Fresh Air Vent Control The Fresh Air Vent allows the air conditioner to recirculate inside air OFF draw air into the room FRESH AIR or exhaust stale air to the outside VENT See Figures 1 2 3 for this operation The OFF position is used when MAXIMUM cooling is desired It may also be for room air re circulation without cooling when the se...

Страница 11: ...olish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner The cabinet front can be removed for more thorough cleaning Refer to Front Installation in this manual Clean the front in a sink using liquid dishwashing detergent and warm water Rinse thoroughly and dry Replace cab...

Страница 12: ...Temperature set too cold for night time cooling To defrost the coil set selector to a FAN position Then set temperature warmer Air conditioner cooling but room is too warm NO ice forming on cooling coil behind decorative front Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too high Set temperature lower Vent set at OPEN position Set vent at C...

Отзывы: