TO TURN UNIT OFF:

DO THIS:

PRESS ON/

OFF BUTTON

Fresh Air Vent Control (On some models)

The Fresh Air Vent allows the air conditioner to:
1. Recirculate inside air - Vent Closed (see Fig. 1)
2. Draw fresh air into the room - Vent Open (see Fig. 2)
3. Exchange air from the room and draws fresh air into the room - Vent and Exhaust

Open (see Fig. 3)

Figure 1 (VENT CLOSED)

Figure 2 (VENT OPEN)

Figure 3 (VENT & EXHAUST OPEN)

ADDITIONAL THINGS YOU SHOULD KNOW

Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with.

• The “Cool “ circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents overheating of the

compressor and possible circuit breaker tripping. The fan will continue to run during this time.

• The control will maintain the set temperature within 2 degrees Fahrenheit, between 60F and 90F degrees.

• The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert from one to the other and back,

press and hold the “TEMP/TIMER” Up ( 

 ) and Down ( 

 ) buttons together for 3 seconds.

Air Conditioner Features

(continued)

SZ000302(En)-YaoKong(1018)

10/25/2004, 2:33 PM

10

Содержание 220201d011

Страница 1: ......

Страница 2: ... of blown fuses repair of loose connections or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs and or fluorescent tubes on models with these features This warranty does not c...

Страница 3: ...tter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Swishing Droplets of water hitting condenser during normal oper...

Страница 4: ... shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper recept...

Страница 5: ...CONTROL OPERATING INSTRUCTIONS Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functions you desire The unit can be controlled by the touch pad alone or with the remote The power supply cord contains a current device that senses damage to the power cord To test your power supply cord do the follo...

Страница 6: ...is pressed the motor speed will slow down at multiple intervals 90 distinct settings to a minimum setting of 10 To speed the motor up press the FASTER button The speed will increase at multiple intervals to a maximum setting of 99 After 5 seconds the control will automatically change back to displaying the set temperature Note Tap or hold either up or down button until the desired temperature is s...

Страница 7: ...7 ...

Страница 8: ...8 ...

Страница 9: ...9 ...

Страница 10: ...e more features in your control that you should become familiar with The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly This prevents overheating of the compressor and possible circuit breaker tripping The fan will continue to run during this time The control will maintain the set temperature within 2 degrees Fahrenheit between 60F and 90F degree...

Страница 11: ... a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaners wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air ...

Страница 12: ...ection To defrost set to FAN ONLY Mode Temperature is set too Low for night time cooling To defrost the coil set to FAN ONLY Mode Then set Tem perature to a Higher setting Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too High Set temperature to a Lower setting Air directional louvers positioned improperly Position louvers for better air dis...

Отзывы: