background image

18

 

Friedrich Air Conditioning Company 

P.O. Box 1540

San Antonio, TX 78295 

210.357.4400

www.friedrich.com

 

PORTABLE AIR CONDITIONERS 

LIMITED WARRANTY

FIRST YEAR 

ANY PART:

  If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from 

date  of  original  purchase,  FRIEDRICH  will  repair  the  product  at  no  charge,  provided  the  product  is  transported  to  a  Friedrich 

Authorized Service Center for repair. ALL transportation charges are the sole responsibility of the owner. This remedy is expressly 

agreed to be the exclusive remedy within twelve months from the date of the original purchase. 

SECOND THROUGH FIFTH YEAR

SEALED REFRIGERANT SYSTEM:

  If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser 

coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in 

your  Room  Air  Conditioner  fails  because  of  a  defect  in  workmanship  or  material  within  sixty  months  from  date  of  purchase, 

FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System;  

PROVIDED

 FRIEDRICH will 

not  pay  the  cost  of  diagnosis  of  the  problem,  removal,  freight  charges,  and  transportation  of  the  air  conditioner  to  and  from  the

Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System.  All such cost will be the 

sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the 

original purchase. 

APPLICABILITY AND LIMITATIONS:

  This warranty is applicable only to units retained within the Fifty States of the U.S.A., District 

of Columbia, and Canada.  This warranty is not applicable to: 

 

1.    Air filters or fuses. 

 

2.    Products on which the model and serial numbers have been removed. 

 

3.    Products  which  have  defects  or  damage  which  results  from  improper  installation,  wiring,  electrical  current 

characteristics, or maintenance;  or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication 

of  the  product  and/or  units  installed  in  a  corrosive  atmosphere,  default  or  delay  in  performance  caused  by    war, 

government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God. 

OBTAINING  WARRANTY  PERFORMANCE:

    Service  will  be  provided  by  the

  FRIEDRICH  Authorized  Dealer  or  Service

Organization

 in your area.  They are listed in the Yellow Pages.  If assistance is required in obtaining warranty performance, write 

to:  Room Air Conditioner Service Manager, Friedrich Air Conditioning Co., P.O. Box 1540, San Antonio, TX 78295-1540. 

LIMITATIONS:    THIS  WARRANTY  IS  GIVEN  IN  LIEU  OF  ALL  OTHER  WARRANTIES.    Anything  in  the  warranty 

notwithstanding,  ANY  IMPLIED  WARRANTIES  OF  FITNESS  FOR  PARTICULAR  PURPOSE  AND/OR  MERCHANTABILITY 

SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY.  MANUFACTURER EXPRESSLY DISCLAIMS AND 

EXCLUDES  ANY  LIABILITY  FOR  CONSEQUENTIAL  OR  INCIDENTAL  DAMAGE  FOR  BREACH  OF  ANY  EXPRESSED  OR 

IMPLIED WARRANTY. 

NOTE:

  Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of 

consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you. 

OTHER:

  This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 

PROOF OF PURCHASE:

  Owner must provide proof of purchase in order to receive any warranty related services. 

All service calls for explaining the operation of this product will be the sole responsibility of the consumer. 

All warranty service must be provided by an 

Authorized FRIEDRICH Service Agency

, unless authorized by FRIEDRICH prior to 

repairs being made. 

 

(7-06)

 

Содержание ZoneAir P012A

Страница 1: ...Service Manual Portable Air Conditioner PORT ServMan 04 09 Model P09A P09B P012A P012B ...

Страница 2: ...TIONING CO Post Office Box 1540 San Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 78218 5212 210 357 4400 FAX 210 357 4490 www friedrich com Printed in the U S A TECHNICAL SUPPORT CONTACT INFORMATION ...

Страница 3: ...rial Number Identification 6 Technical Specifications 7 Precautions for use 8 Control Panel Operation 9 Remote Control Operation 10 Window Adapter Kit Installation 11 12 Condensation Handling 13 Maintenance and Service 14 Troubleshooting 15 Refrigeration System Diagram 16 Wiring Diagrams 17 Warranty 18 1 ...

Страница 4: ...ssistant if possible Capacitors even when disconnected from the electrical power source retain an electrical charge potential capable of causing electric shock or electrocution Handle discharge and test capacitors according to safe established standards and approved procedures Extreme care proper judgment and safety procedures must be exercised if it becomes necessary to test or troubleshoot equip...

Страница 5: ...t contact with liquid refrigerant can result in minor to moderate injury Be extremely careful when using an oxy acetylene torch Direct contact with the torch s flame or hot surfaces can cause serious burns Make sure to protect personal and surrounding property with fire proof materials Have a fire extinguisher at hand while using a torch Provide adequate ventilation to vent off toxic fumes and wor...

Страница 6: ... and or minor to serious property damage 4 INTRODUCTION This service manual is designed to be used in conjunction with the installation manuals provided with each unit This service manual was written to assist the professional HVAC service technician to quickly and accurately diagnose and repair any malfunctions of this product This manual therefore will deal with all subjects in a general nature ...

Страница 7: ...unit INTRODUCTION 5 1 Control panel 2 Air outlet 3 Signal receptor 4 Handle 5 Caster 6 Air outlet hose 7 Air filter 8 Air intake hose 9 1 2 water outlet drain 10 Power supply cord ...

Страница 8: ...Manufactured L 0 C 3 F 6 J 9 A 1 D 4 G 7 B 2 E 5 H 8 Year Manufactured A 1 D 4 G 7 K 0 B 2 E 5 H 8 C 3 F 6 J 9 Month Manufactured A Jan D Apr G Jul K Oct B Feb E May H Aug L Nov C Mar F Jun J Sept M Dec L H G K 00001 Production Run Number Product Line R RAC RAC SERIAL NUMBER IDENTIFICATION GUIDE MODEL NUMBER CODE Unit MODEL AND SERIAL Number Unit Identification P 09 A ...

Страница 9: ...2 212 18 40 5 80 125V 15A 5 15P P12A 11500 115 60 10 5 1280 19 5 x 33 6 x 15 5 4 2 235 24 7 40 5 86 125V 15A 5 15P Model Cooling Capacity BTU h Voltage Hz Amps Watts Dimensions W x H x D Dehumidification Pints Hour Indoor Air Circulation CFM Refrigerant Charge 410 A Locked Rotor Amps Net Weight lbs Circuit Rating Plug Face NEMA P09B 10000 115 60 10 8 1200 19 25 x 33 62 x 15 55 4 2 224 21 2 50 77 2...

Страница 10: ...nterference Ensure that the discharge air outlet is free from obstructions and not impeded by walls or other structures Operate the unity ONLY in the upright position When unplugging the unit hold the power plug securely and pull it out carefully Do not use damaged or improper AC socket Do not use the unit near gas appliances or in the vicinity of flammable liquids Failure to follow this warning c...

Страница 11: ...ER USE EXTENSION CORDS TO OPERATE AN AIR CONDITIONER TEST RESET Test Button Reset Button Mode control The mode control has three settings Cool Dehumidify and Fan The settings are adjusted with the Mode Control button A light will indicate which setting is currently being used Cooling operation 1 Press MODE button to choose the cooling mode LCD window will show cool During the cooling operation alw...

Страница 12: ...tion can be accessed from the remote control Battery replacement Remove the cover on the back of the remote control and insert the batteries with the and poles pointing in the proper direction CAUTION Use only AAA or IEC R03 1 5V batteries Remove the batteries if the remote control is not used for a month or longer Do not attempt to recharge the supplied batteries All batteries should be replaced ...

Страница 13: ...hese parts and ensure that all parts are present Window panel Attaches to window opening to allow air exchange for system air transfer Window panel extensions Extends window panel to fit windows of various dimensions Tube adapters Connect air exchange tubes to window panel Screws 12 screws are included for assembling the window adapter kit Some screws may be partially assembled onto window panel A...

Страница 14: ...ontally This installation may also be used for crank style windows 3 Tighten the four screws on the window panel to secure the window panel extensions 4 Close window 5 The window adapter kit should now fit securely within the window frame and you can now attach the air exchange tubes Ifyouarehavingtroubleattachingtheairexchange tubes you may attach the tubes prior to installing the window adapter ...

Страница 15: ...drained from the unit by removing the base stopper and letting the water drain by gravity 1 When the WATER FULL lamp is on unplug the unit and move the unit to a suitable location for draining the condensation 2 Using the gravity drain method ensure that the base stopper is located above a suitable area for draining the condensate and remove the stopper Re install the stopper once all water has dr...

Страница 16: ...he air filter 1 Pull the filter out as shown in the drawing 2 Take out the air filter from the filter cover 3 Wash the air filter by immersing it gently into warm about 40 C or 104 F water with a neutral detergent or vacuum the filter clean 4 Rinse the filter and dry it thoroughly in a shaded place 5 Install the air filter back to its original place Cleaning the air conditioner Clean the surface o...

Страница 17: ...TROUBLESHOOTING 15 ...

Страница 18: ...16 TROUBLESHOOTING The compressor bolts are loose or copper tubes are contacting other metal parts Tighten bolts Adjust copper tubes Unblock below72 F ...

Страница 19: ...17 REFRIGERATOR SYSTEM DIAGRAM SCHEMATIC WIRING DIAGRAM ...

Страница 20: ...uses 2 Products on which the model and serial numbers have been removed 3 Products which have defects or damage which results from improper installation wiring electrical current characteristics or maintenance or caused by accident misuse or abuse fire flood alterations and or misapplication of the product and or units installed in a corrosive atmosphere default or delay in performance caused by w...

Страница 21: ......

Страница 22: ...20 ...

Страница 23: ...TIONING CO Post Office Box 1540 San Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 78218 5212 210 357 4400 FAX 210 357 4490 www friedrich com Printed in the U S A TECHNICAL SUPPORT CONTACT INFORMATION ...

Страница 24: ...AIR CONDITIONING CO Post Office Box 1540 San Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 78218 5212 210 357 4400 FAX 210 357 4490 www friedrich com Printed in the U S A PORT ServMan 04 09 ...

Отзывы: