26
27
CAUTION
Excessive Weight Hazard
Use two or more people when installing your
air conditioner.
Failure to do so can result in back or other
injury.
STEP 1.
Check the sleeve to be certain it has been correctly installed
in the wall. Remove the front panel on the WSE SLEEVE.
Remove the rear WEATHER PANEL. Reverse grille. Place
lower edge into sleeve tab (Friedrich logo facing out). Align
slots with the screw holes. Secure grille with screws.
A.
Check the anchor screw. There should be four (4) in the WSE
SLEEVE (two in each side).
B.
Determine if the sleeve has a downward slope of
3
/
8
″ to the
outside. See Page 26 for further details.
C.
Check to be sure the sleeve has been sealed around all
edges with an industrial type caulking on both the outside
and inside to prevent rain entry.
STEP 3.
Check the electrical receptacle to see that it conforms to the
requirements for the chassis model to be installed. See Page 5
for the receptacle requirements.
STEP 3.
Remove the chassis from the shipping carton. Lift the chassis
by the basepan and slide it into the front of the sleeve. (Obtain
assistance as needed.) Push the chassis all the way into the
sleeve, using the plastic front handles, so that the front panel
meets the front edge of the shell.
NOTE:
Chassis comes with pre-installed seal gasket.
WallMaster Chassis Installation Instructions
for WCT, WET and WHT models
CAUTION
Cut/Sever
Although great care has been
taken to minimize sharp edges
in the construction of your unit,
use gloves or other hand
protection when handling unit
Failure to do so can result in minor
to moderate personal injury.
Figure 51