STEP 3
WALL PREPARATION:
The maximum wall thickness permissible without special construction is de ter mined by
the model size to be installed. THE OUTSIDE CABINET CONDENSER-AIR-INTAKE-LOU VERS MUST NOT BE
BLOCKED BY EXTENDING INSIDE THE WALL AREA. Observe the maximum wall thickness shown in the chart
and di a gram in Figure B.
SPECIAL INSTRUCTIONS FOR EXTRA THICK WALLS:
For installation in walls exceeding the max i mum thickness
shown in the chart, the following suggested construction may apply.
FIGURE B
TOP VIEW
2" MINIMUM
BOTH SIDES
CONDENSER AIR
INTAKE LOUVERS
MAXIMUM WALL
THICKNESS
CONDENSER
AIR INTAKE
LOUVERS
TOP VIEW SHOW ING
BEVELED SIDES FOR
AIR INTAKE. WALL
BELOW UNIT MUST BE
BEVELED ALSO.
STEP 4
CHECKING WIRING AND PLUMBING: Check all wiring and plumbing inside and outside of the wall to be sure none
will be broken where the hole is to be cut.
STEP 5
HOLE CONSTRUCTION: Depending upon size of unit to be installed, lay out the hole dimensions per the chart below. Cut
and frame in hole to fi nished dimensions. Use 2" x 4" material for framing and follow the suggested typical installations in
Figure C, D, or E on page 12.
NOTE: IF THE WALL CONSTRUCTION IS TYPICAL FRAME OR 2 X 4 STUDDING WITH BRICK OR STONE VENEERS, LO-
CATE THE HOLE NEXT TO ONE OF THE STUDS. FOR MASONRY, CONCRETE OR CINDER BLOCK WALLS, LOCATE HOLE
FOR CONVENIENCE.
EXTRA THICK WALL CON STRUC TION
NOTE: THESE DIMENSIONS ARE FOR FINISHED HOLE SIZE.
CONDITIONED ROOM SIDE AIR
CONDENSER AIR
OUTLET
REJECTED HEATED
AIR
NOTE: Condenser air inlets and
outlet must be unobstructed
to avoid the recirculation of
rejected heated air.
MODEL
A
SMALL CHASSIS
7 ⅜"
MEDIUM CHASSIS
7 ⅜"
LARGE CHASSIS
15 ⅛"
FINISHED SMALL
MEDIUM
LARGE
DIMENSION
CHASSIS
CHASSIS
CHASSIS
A
16
3
⁄
16
" 18
3
⁄
16
" 20
3
⁄
16
"
B
26
3
⁄
16
" 26
3
⁄
16
" 28
1
⁄
2
"