En-3

NAME OF PARTS

  Refer to the folded out page on the cover.

Fig. 6 Remote Control Unit

I

SLEEP button

J

MASTER CONTROL button

K

SET TEMP. button ( 

 

/

 

 

)

L

Signal Transmitter

M

TIMER MODE button

N

TIMER SET ( 

 / 

 ) button

O

FAN CONTROL button

P

START/STOP button

Q

SET button (Vertical)

R

SET button (Horizontal)

S

SWING button

T

RESET button

U

TEST RUN button

This button is used when installing the
conditioner, and should not be used un-
der normal conditions, as it will cause the
air conditioner’s thermostat function to op-
erate incorrectly.

If this button is pressed during normal op-
eration, the unit will switch to test opera-
tion mode, and the Indoor Unit’s OPERA-
TION Indicator Lamp and TIMER Indicator
Lamp will begin to flash simultaneously.

To stop the test operation mode, press the
START/STOP button to stop the air condi-
tioner.

V

CLOCK ADJUST button

W

Remote Control Unit Display (Fig. 7)

X

Transmit Indicator

Y

Clock Display

Z

Operating Mode Display

[

Timer Mode Display

\

Fan Speed Display

]

Temperature SET Display

`

SLEEP Display

a

SWING Display

Fig. 1 Indoor Unit

1

Operating Control Panel (Fig. 2)

2

MANUAL AUTO button

When kept on pressing the MANUAL
AUTO button for more than 10 seconds,
the forced cooling operation will start.

The forced cooling operation is used at the
time of installation.
Only for authorized service personnel's
use.

When the forced cooling operation starts
by any chance, press the START/STOP but-

ton to stop the operation.

3

Indicator (Fig. 3)

4

Remote Control Signal Receiver

5

OPERATION Indicator Lamp (red)

6

TIMER Indicator Lamp (green)

If the TIMER indicator lamp flashes when
the timer is operating, it indicates that a
fault has occurred with the timer setting

(See Page 13 Auto Restart).

7

SUPER QUIET Indicator Lamp (orange)

8

Intake Grille (Fig. 4)

9

Front Panel

0

Air Filter

A

Air Flow Direction Louver

B

Power Diffuser

C

Right-Left Louver

(behind Air Flow Direction Louver)

D

Drain Hose

Fig. 5 Outdoor Unit

E

Intake Port

F

Outlet Port

G

Pipe Unit

H

Drain port (bottom)

Содержание MR24C3F

Страница 1: ...an ais Espa ol Indoor Unit MW24C3F MW30C3F MW36C3F Outdoor Unit MR24C3F MR30C3F MR36C3F INVERTER COOLING MODEL ROOM AIR CONDITIONER WALL MOUNTED TYPE Friedrich Air Conditioning Co 4200 N Pan Am San An...

Страница 2: ...paratus When installing the indoor and outdoor unit take precautions to prevent access to infants Do not use inflammable gases near the air conditioner DANGER CAUTION En 1 OPERATION TIMER SUPER QUIET...

Страница 3: ...matically turns off WIRELESS REMOTE CONTROL UNIT The Wireless Remote Control Unit allows convenient con trol of air conditioner operation HORIZONTAL AIRFLOW For cooling use horizontal airflow so the c...

Страница 4: ...smit Indicator Y Clock Display Z Operating Mode Display Timer Mode Display Fan Speed Display Temperature SET Display SLEEP Display a SWING Display Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 M...

Страница 5: ...direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST b...

Страница 6: ...a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 O Each time the button is pressed the fan speed changes in the follow...

Страница 7: ...tion Cooling to adjust the temperature to the value set in the thermostat The monitor operation range is 4 F relative to the thermostat set ting If the mode automatically selected by the unit is not w...

Страница 8: ...conds later the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one trans...

Страница 9: ...ing during sleep the SLEEP timer function automatically modifies the thermostat setting in accord ance with the set time setting When the set time has elapsed the air conditioner completely stops Duri...

Страница 10: ...e automatically returned to the 3 range When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Ve...

Страница 11: ...rding to the current airflow direc tion Airflow direction is 1 4 for cooling dry With the upper airflow direction louver in the horizontal position the lower airflow direction louver moves swings to d...

Страница 12: ...lle 1 Align the sides of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of exam...

Страница 13: ...itted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted...

Страница 14: ...erly OPERATING TIPS If the problem persists after performing these checks or if you notice burning smells or both the ORERATION Indicator Lamp Fig 3 5 and the TIMER Indicator Lamp Fig 3 6 flashes or o...

Страница 15: ...lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air ci...

Страница 16: ......

Страница 17: ......

Страница 18: ......

Отзывы: