background image

En-11

Cleaning the Intake Grille

1. Remove the Intake Grille.

1

Place your fingers at both lower ends of the grille
panel, and lift forward; if the grille seems to catch
partway through its movement, continue lifting up-
ward to remove.

2

Pull past the intermediate catch and open the Intake
Grille wide so that it become horizontal.

2. Clean with water.

Remove dust with a vacuum cleaner; wipe the unit with
warm water, then dry with a clean, soft cloth.

3. Replace the Intake Grille.

1

Pull the knobs all the way.

2

Hold the grille horizontal and set the left and right
mounting shafts into the bearings at the top of the
panel.

3

Press the place where the arrow on the diagram indi-
cates and close the Intake Grille.

1

2

CLEANING AND CARE

Before cleaning the air conditioner, be sure to turn it off and disconnect the Power Supply Cord.

Be sure the Intake Grille (Fig. 1 

8

) is installed securely.

When removing and replacing the air filters, be sure not to touch the heat exchanger, as per-
sonal injury may result.

 CAUTION!

Cleaning the Air Filter

1. Open the Intake Grille, and remove the air

filter.

Lift up the air filter’s handle, disconnect the two lower
tabs, and pull out.

2. Remove dust with a vacuum cleaner or by

washing.

After washing, allow to dry thoroughly in a shaded place.

3. Replace the Air Filter and close the Intake

Grille.

1

Align the sides of the air filter with the panel, and push
in fully, making sure the two lower tabs are returned
properly to their holes in the panel.

2

Close the Intake Grille.

(For purposes of example, the illustration shows the unit
without Intake Grille installed.)

Dust can be cleaned from the air filter either with a vacuum
cleaner, or by washing the filter in a solution of mild de-
tergent and warm water. If you wash the filter, be sure to
allow it to dry thoroughly in a shady place before rein-
stalling.

If dirt is allowed to accumulate on the air filter, air flow
will be reduced, lowering operating efficiency and increas-
ing noise.

During periods of normal use, the Air Filters should be
cleaned every two weeks.

When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the
unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service
personnel.

When cleaning the unit’s body, do not use water hotter than 104 °F, harsh abrasive cleansers, or volatile agents like
benzene or thinner.

Do not expose the unit body to liquid insecticides or hairsprays.

When shutting down the unit for one month or more, first allow the fan mode to operate continuously for about one-half
day to allow internal parts to dry thoroughly.

Intake Grille

Air filter handle

Hooks (two places)

Intake
Grille

Hooks (two places)

Intake Grille

Mounting

shaft

Knob

Intake Grille

Bearing

Mounting shaft

Knob

1

2

2

1

Mounting

shaft

Knob

Содержание MR24C3F

Страница 1: ...an ais Espa ol Indoor Unit MW24C3F MW30C3F MW36C3F Outdoor Unit MR24C3F MR30C3F MR36C3F INVERTER COOLING MODEL ROOM AIR CONDITIONER WALL MOUNTED TYPE Friedrich Air Conditioning Co 4200 N Pan Am San An...

Страница 2: ...paratus When installing the indoor and outdoor unit take precautions to prevent access to infants Do not use inflammable gases near the air conditioner DANGER CAUTION En 1 OPERATION TIMER SUPER QUIET...

Страница 3: ...matically turns off WIRELESS REMOTE CONTROL UNIT The Wireless Remote Control Unit allows convenient con trol of air conditioner operation HORIZONTAL AIRFLOW For cooling use horizontal airflow so the c...

Страница 4: ...smit Indicator Y Clock Display Z Operating Mode Display Timer Mode Display Fan Speed Display Temperature SET Display SLEEP Display a SWING Display Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 M...

Страница 5: ...direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST b...

Страница 6: ...a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 O Each time the button is pressed the fan speed changes in the follow...

Страница 7: ...tion Cooling to adjust the temperature to the value set in the thermostat The monitor operation range is 4 F relative to the thermostat set ting If the mode automatically selected by the unit is not w...

Страница 8: ...conds later the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one trans...

Страница 9: ...ing during sleep the SLEEP timer function automatically modifies the thermostat setting in accord ance with the set time setting When the set time has elapsed the air conditioner completely stops Duri...

Страница 10: ...e automatically returned to the 3 range When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Ve...

Страница 11: ...rding to the current airflow direc tion Airflow direction is 1 4 for cooling dry With the upper airflow direction louver in the horizontal position the lower airflow direction louver moves swings to d...

Страница 12: ...lle 1 Align the sides of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of exam...

Страница 13: ...itted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted...

Страница 14: ...erly OPERATING TIPS If the problem persists after performing these checks or if you notice burning smells or both the ORERATION Indicator Lamp Fig 3 5 and the TIMER Indicator Lamp Fig 3 6 flashes or o...

Страница 15: ...lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air ci...

Страница 16: ......

Страница 17: ......

Страница 18: ......

Отзывы: