9
ENGLISH
Select the best Location
- There should not be any heat or steam near
the unit.
- Select a place where there are no obstacles
around the unit.
- Make sure that condensation drainage can
be conveniently routed away.
- Do not install near a doorway.
- Ensure that the gap between a wall and the
left (or right) of the unit is more than 4in. The
unit should be installed as high as possible
on the wall, allowing a minimum of 8in from
ceiling.
- Use a metal detector to locate studs to pre-
vent unnecessary damage to the wall.
* Recommended height 6.5ft from the floor.
* The feature can be changed according to the
type of model.
- If an awning is built over the unit to prevent
direct sunlight or rain exposure, make sure
that heat radiation from the condenser is not
restricted.
- Ensure that the space around the back side
and other sides is more than 12in. The space
in front of the unit should be more than 28in.
- Do not place animals and plants in the path
of the warm air.
- Take the weight of the air conditioner into
account and select a place where noise and
vibration are minimum.
- Select a place where the warm air and noise
from the air conditioner do not disturb neigh-
bors.
More than 8
More than
4
More than
4
(Unit : in)
More than
12
More than
12
Sunr
oof
Fence or
obstacles
More than
28
More than
24
(Unit : in)
INSTALLATION
NOTE
!
Remove obstructions to prevent blockage
of airflow path.
Indoor unit
Outdoor unit