180
PB
COMPONENTS TESTING
Field Settings (Function Settings)
Instructions for the function setting of acces s control, fire protection , ON/OFF
1. Factory setting
ON/OFF function is disabled as factory default while both the access control and fire protectio n
functions are enabled.
To use or cancel the ac cess control / fire protection / (ON/O FF ) function , use the wired controller to
modify the parameter s of indoo r unit.
Note :
Pleas e refer to “Indoo r unit paramete r revise” sectio n in TC Manua l for how to use the wired controller
to modify the parameter s of indoo r unit
.
2. Functio n introduction
3. Function setting
(1) Hardware connection
Figure 1 electrica l wiring diagram
Figure 2 short wiring
(1) Acces s control:
C ontrol mod e to control the machin e startup & shutdow n base d on the ON and OFF state of the
access control port.
(2) Fire protection :
C ontrol mod e to control the machine startup & shutdow n base d on the ON and OFF state of the fire
protectio n port.
(3) ON/OFF :
Specia l control mod e to achie ve the control of indoo r unit startup & shutdown based on the input
state of the fire protection port of the indoo r unit (no other way can control startup & shutdown) and
output the fault status of indoo r unit through OU T INPU T port.
Figure 3 main control board
3 pins of the OU T INPU T X2 socke t show n in the electrica l wiring diagram of Figure 1 will be in short
circuited state by def ault factory setting (an externa l short circuit plug show n in Figure 2, and the OU T
INPUT X2 socke t of main control board as show n in Figure 3 ).
(Note: the socket number in circuit is subjec t to the actua l serial number of PC B.)
Содержание FPCG0912
Страница 9: ...9 INTRODUCTION Product Appearance Cassette type Model Btu h Indoor Unit Out door Unit 24K 36K...
Страница 119: ...119 OPERATION Figure 301 Remote Control Operation and Function...
Страница 132: ...132 INSTALLATION Outdoor Units Fig 432 Fig 433...
Страница 140: ...140 MAINTENANCE...
Страница 163: ...163 COMPONENTS TESTING Fan Motor Fig 605...
Страница 200: ...200 WIRINGDIAGRAMS 7k Wall Units...
Страница 203: ...203 WIRING DIAGRAMS 24k Outdoor Units Electric wiring diagram 1993419 E...
Страница 204: ...204 WIRING DIAGRAMS 36k Outdoor Units...
Страница 205: ...205 PARTSCATALOG 18K Outdoor Condensor...
Страница 206: ...206 PARTSCATALOG 18K Outdoor Condensor...
Страница 207: ...207 PARTSCATALOG 18K Outdoor Condensor...
Страница 210: ...210 PARTSCATALOG 24K Outdoor Condensor Figure 901A 4 C 4x12...
Страница 211: ...211 PARTS CATALOG 24K Outdoor Condensor Figure 901B 1 1 1 I I i I I _ ____ I L i...
Страница 212: ...212 PARTS CATALOG 24K Outdoor Condensor Figure 901C II c tx12 II...
Страница 215: ...215 PARTS CATALOG 36K Outdoor Condensor Figure 902A 11 I i i r I h 1 1 I I _ I 11 12 11 I I I Ii I 1 I Ii L l_ ii I _...
Страница 216: ...216 PARTS CATALOG 36K Outdoor Condensor Figure 902B i...
Страница 217: ...217 PARTS CATALOG 36K Outdoor Condensor Figure 902C u...
Страница 222: ...222 PARTS CATALOG 9K 12K Indoor Cassette Figure 904 B M4x08...
Страница 226: ...226 PARTS CATALOG 24K INDOOR CASSETTE FIgure 906 0 1 A 4X8 13 19 NOTE I I r 1 I I iA 4X12 t I 9 5X53 11 4 _ _ A 4X10...
Страница 228: ...228 PARTS CATALOG 9K 12K DUCTED INDOOR Figure 907a...
Страница 229: ...229 Figure 907b PARTS CATALOG 9K 12K DUCTED INDOOR...
Страница 230: ...230 Figure 907c PARTS CATALOG 9K 12K DUCTED INDOOR...
Страница 232: ...232 PARTS CATALOG 18K Ducted Indoor Figure 908a...
Страница 233: ...233 PARTS CATALOG 18K Ducted Indoor Figure 908b...
Страница 234: ...234 PARTS CATALOG 18K Ducted Indoor Figure 908c...
Страница 236: ...236 PARTS CATALOG 24k Ducted Indoor Figure 909a _ _ _ 1...
Страница 237: ...237 PARTS CATALOG 24k Ducted Indoor Figure 909b _ _ __lllfllllllllllalll l rla _ fllll _ 2...
Страница 238: ...238 PARTS CATALOG 24k Ducted Indoor Figure 909c A __ _ _ C llillllp_ ___ 111 11111111111A11 _ lffllllllal 3...