9
Thermostat Installation
Installing the Wireless Control Card
➤
Unplug the PTAC/Vert-I-Pak* unit from power supply
➤
Connect the low voltage wires to screw terminals on the PTAC/Vert-I-Pak*
unit low voltage terminal block - refer to the Wiring Table to determine
proper connections.
➤
Mount the control card to the PTAC/Vert-I-Pak* unit.
Ensure that the Wireless Control Card antenna is not touching any metal
components of the PTAC/Vert-I-Pak* unit.
Ensure that the Wireless Control Card Antenna is facing the thermostat on
the wall and is oriented so that any metal parts of the PTAC/Vert-I-Pak* unit
do not obstruct the wireless communication to the thermostat and, in case
of a network installation, to other wireless control cards and the server.
Ensure that the control card is secured and cannot fall into the
PTAC/Vert-I-Pak* unit Condensation Pan.
➤
Plug in the PTAC/Vert-I-Pak* unit to power supply.
NOTE: If the PTAC/Vert-I-Pak* unit has only one (1) fan speed, connect both fan
control wires – Green and Purple – to the fan terminal (G).
Wiring Table - 24V AC
Wire
Color
Terminal
Letter
Terminal
Connection
Black
C
Common
Red
R
24V
Yellow
Y
Compressor
White
W
Heat
Orange
O or B
Reverse Valve
Green
GH
Fan High
Purple
GL
Fan Low
Wiring Table - 24V DC
Wire
Color
Terminal
Letter
Terminal
Connection
Black
R
24V
Red
C
Common
Yellow
Y
Compressor
White
W
Heat
Orange
O or B
Reverse Valve
Green
GH
Fan High
Purple
GL
Fan Low
* The wireless control card should never be installed inside the metal electrical control
enclosure/box of the PTAC/Vert-I-Pak unit. Failure to comply will result in obstruction to the
wireless communication. The control card is always to be mounted as shown on the pictures
on the next page.