11
01 – FAN CONTROL MODE
Select Fan Control Mode:
00
MANUAL - fguest can select automatic or continuous fan mode;
01
* AUTOMATIC - fan runs only when there is a demand for heating or air conditioning;
*
Indicates factory setting;
Custom Energy Savings Settings
02 – 1
ST
STAGE DIFFERENTIAL - HEAT
02-30 (0.2°F - 3.0°F; 0.5°F* factory setting) Select the number of degrees the thermostat
has to sense between the automatic changeover temperature for heat and the room
temperature before a call for the 1st stage heating is initiated.