background image

Friedrich Air Conditioning Company 

P.O. Box 1540

San Antonio, TX 78295 

210.357.4400

www.friedrich.com

ROOM AIR CONDITIONERS 

LIMITED WARRANTY

FIRST YEAR 

ANY PART:

  If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from 

date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible

for  service.    Any  additional  labor  cost  for  removing  inaccessible  units  and/or  charges  for  mileage  related  to  travel  by  a  Service

Agency that exceeds 25 miles one way will be the responsibility of the owner. This remedy is expressly agreed to be the exclusive

remedy within twelve months from the date of the original purchase. 

SECOND THROUGH FIFTH YEAR

SEALED REFRIGERANT SYSTEM:

  If the Sealed Refrigeration System (defined  for this purpose as the compressor, condenser 

coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in 

your  Room  Air  Conditioner  fails  because  of  a  defect  in  workmanship  or  material  within  sixty  months  from  date  of  purchase, 

FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System;  

PROVIDED

 FRIEDRICH will 

not  pay  the  cost  of  diagnosis  of  the  problem,  removal,  freight  charges,  and  transportation  of  the  air  conditioner  to  and  from  the

Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System.  All such cost will be the 

sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the 

original purchase. 

APPLICABILITY AND LIMITATIONS:

  This warranty is applicable only to units retained within the Fifty States of the U.S.A., District 

of Columbia, and Canada.  This warranty is not applicable to: 

 

1.    Air filters or fuses. 

 

2.    Products on which the model and serial numbers have been removed. 

 

3.    Products  which  have  defects  or  damage  which  results  from  improper  installation,  wiring,  electrical  current 

characteristics, or maintenance;  or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication 

of  the  product  and/or  units  installed  in  a  corrosive  atmosphere,  default  or  delay  in  performance  caused  by    war, 

government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God. 

OBTAINING  WARRANTY  PERFORMANCE:

    Service  will  be  provided  by  the

  FRIEDRICH  Authorized  Dealer  or  Service

Organization

 in your area.  They are listed in the Yellow Pages.  If assistance is required in obtaining warranty performance, write 

to:  Room Air Conditioner Service Manager, Friedrich Air Conditioning Co., P.O. Box 1540, San Antonio, TX 78295-1540. 

LIMITATIONS:    THIS  WARRANTY  IS  GIVEN  IN  LIEU  OF  ALL  OTHER  WARRANTIES.    Anything  in  the  warranty 

notwithstanding,  ANY  IMPLIED  WARRANTIES  OF  FITNESS  FOR  PARTICULAR  PURPOSE  AND/OR  MERCHANTABILITY 

SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY.  MANUFACTURER EXPRESSLY DISCLAIMS AND 

EXCLUDES  ANY  LIABILITY  FOR  CONSEQUENTIAL  OR  INCIDENTAL  DAMAGE  FOR  BREACH  OF  ANY  EXPRESSED  OR 

IMPLIED WARRANTY. 

Performance of Friedrich’s Warranty obligation is limited to one of the following methods: 

 

1.  Repair of the unit 

 

2.  A refund to the customer for the prorated value of the unit based upon the remaining warranty period of the unit. 

3.  Providing a replacement unit of equal value 

The method of fulfillment of the warranty obligation is at the sole discretion of Friedrich Air Conditioning. 
NOTE:

  Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of 

consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you. 

OTHER:

  This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 

PROOF OF PURCHASE:

  Owner must provide proof of purchase in order to receive any warranty related services. 

All service calls for explaining the operation of this product will be the sole responsibility of the consumer. 

All warranty service must be provided by an 

Authorized FRIEDRICH Service Agency

, unless authorized by FRIEDRICH prior to 

repairs being made. 

 (10-08) 

15

Содержание CP15F10

Страница 1: ...Compact Programmable CP 15 18 24 ServParts 05 10 Model 2010 Service Parts Manual R410A Models ...

Страница 2: ... Box 1540 San Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 78218 5212 210 357 4400 877 599 5665 x 846 FAX 210 357 4490 Email tac friedrich com www friedrich com Printed in the U S A TECHNICAL SUPPORT CONTACT INFORMATION ...

Страница 3: ...pecifications 4 How to Operate the Air Conditioner with Remote Control 5 Method of Charging Repairs 6 Compressor Replacement 7 Troubleshooting 8 10 Wiring Diagrams for 2010 Model 11 Exploded View of Parts for 2010 Model 12 Parts for 2010 Models 13 14 Warranty 15 ...

Страница 4: ...Jul K Oct B Feb E May H Aug L Nov C Mar F Jun J Sept M Dec 3rd and 4th Digit Approximate BTU HR Cooling Heating BTU Hr capacity listed in the Specification Performance Data Section 7th Digit Options 0 Straight Cool Heat Pump Models 6th Digit Voltage 1 115 Volts 3 230 208 Volts 5th Digit Alphabetical Modifier COMPACT PROGRAMMABLE Model Number Code C P 15 F 1 0 RAC Serial Number Identification Guide...

Страница 5: ... electrical ratings on unit s rating plate Proper circuit protection is the responsibiity of the homeowner Grounding Unit MUST be grounded from branch circuit through service cord to unit or through separate ground wire provided on permanently connected units Be sure that branch circuit or general purpose outlet is grounded Ground wire must be connected to ground screw located in lower right corne...

Страница 6: ...lary Capillary Starting Method Working Temp Range 64 110 64 110 64 110 Condenser Aluminum fin copper Aluminum fin copper Aluminum fin copper Pipe Diameter inch Rows Fin Gap inch 2 1 20 2 1 20 2 1 20 Coil length l xheight H xcoil width 27 7 X15 75 X 1 34 X15 75X 34X15 75X1 Fan Type Piece Axial fan 1 Axial fan 1 Axial fan 1 Fan Diameter inch 15 6 15 6 15 6 Sound Pressure Level dB A H M L 61 60 58 61...

Страница 7: ...panel will flash 2 Press the plus or minus button to change the delay time from 1 to 24 hours 3 Press TIMER again or wait 10 seconds Indicator light on air conditioner control panel will remain on To set Timer to turn onair conditioner keepingprevious settings 1 Turn off air conditioner 2 Press TIMER Indicator light on air conditioner control panel will flash 3 Press the plus or minus button to ch...

Страница 8: ...RD FREEZE HAZARD Proper safety procedures must be followed and proper protective clothing must be worn when working with a torch Failure to follow these procedures could result in moderate or serious injury WARNING BURN HAZARD Method Of Charging Repairs The acceptable method for charging the RAC system is the Weighed in Charge Method The weighed in charge method is applicable to all units It is th...

Страница 9: ...w slight the system will need to be cleaned up following proper procedures 7 Install the replacement compressor 8 Pressurize with nitrogen and leak test all connections with an electronic or Halide leak detector Recover refrigerant and repair any leaks found Repeat Step 8 to insure no more leaks are present Unplug and or disconnect all electrical power to the unit before performing inspections mai...

Страница 10: ...ce coil check for leak Inoperative fan motor Test fan motor replace if inoperative Partially restricted capillary tube De ice coil Check temp differential delta T across coil Touch test coil return bends for same temp Test for low running current n o i t c A e s u a C e l b i s s o P m e l b o r P Compressor runs continually does not cycle off Excessive heat load Unit undersized Test cooling perfo...

Страница 11: ...ck if unit operates If unit operates replace t stat Loose or broken parts in t stat Check as above Incorrect wiring Refer to appropriate wiring diagram Defective thermistor Replace thermistor or electronic control board n o i t c A e s u a C e l b i s s o P m e l b o r P Noisy operation Poorly installed Refer to Installation Manual for proper installation Fan blade striking chassis Reposition adju...

Страница 12: ...g structure particularly floors Advise customer n o i t c A e s u a C e l b i s s o P m e l b o r P Thermistor short cycles Defective thermistor Replace thermistor or electronic control board Plenum gasket not sealing allowing discharge air to short cycle unit Check gasket Reposition or replace as needed Restricted coil or dirty filter Clean advise customer of periodic cleaning maintenance needs of ...

Страница 13: ...11 ELECTRONIC CONTROL WIRING DIAGRAM 2010 MODEL CP15F10 CP18F30 CP24F30 ...

Страница 14: ...EXPLODED VIEW AND LIST OF PARTS 2010 MODEL CP15F10 CP18F30 AND CP24F30 12 ...

Страница 15: ... r e v u o L e d i u G 2 6 67700230 63 Filter 1 67700231 4 1 r e v u o L e d i u G 4 6 67700232 65 Front Case 1 67700233 66 Front Panel 1 67700234 1 l e n a P w o d n i W S A 7 6 67700235 1 l e n a P r e v o C e t o m e R 8 6 67700236 1 s i s s a h c n a p e s a B 9 6 67700296 1 r e x i F s i s s a h C 0 7 67700105 71 Remote Control 1 67700171 1 Supporter Assy 1 67700132 2 Self threading Screw ST4...

Страница 16: ... L g n i w S 1 3 67700124 1 r e v u o L g n i w S r o t o M 2 3 67700133 1 s i x A l a n o i t c e l f n I 3 3 67700121 1 t r o p p u S g n i w S 4 3 67700125 1 r o o D r i A h s e r F 5 3 67700212 1 l e e h W r e w o l B 6 3 67700243 1 d r a o b p a l c e c i f i r O 7 3 67700108 67700106 1 y s s A r o t a r o p a v E 9 3 67700266 1 r e d l o H r o s n e S 0 4 67700213 67700290 67700293 3 8 M r e...

Страница 17: ...allation wiring electrical current characteristics or maintenance or caused by accident misuse or abuse fire flood alterations and or misapplication of the product and or units installed in a corrosive atmosphere default or delay in performance caused by war government restrictions or restraints strikes material shortages beyond the control of FRIEDRICH or acts of God OBTAINING WARRANTY PERFORMANC...

Отзывы: