background image

13

1

2

3

3

4

5

6

7

8

9

1.         

Power

: Turn the air conditioner on and off. This button will 

    clear the TIMER setting.

2. 

MODE:

 Press the button to select the mode of operation, AUTO, COOL, 

    DRY, FAN ONLY, HEAT.
  

  Note: 

The HEAT mode is only for some heating models. If you do not 

    need it, press the MODE button for more than 5 seconds to delete the 
    HEAT function, and the COOL mode will be selected automatically. 
    Press the MODE again for more than 5 seconds to add the HEAT 
    function, and the HEAT mode will be selected automatically. 

3.       And      : Use these buttons to increase or decrease the setting 
    Temperature or Timer. Setting temperature range: 61 ~88

 or 16 ~31

.

 

   Note:

 When the remote controller is turn-off, press       and      buttons can 

    pre-set the temperature. After the setting, the remote temperature display 
    will be off after a while.

4. 

TURBO:

 When the remote is ON, press the button to active the TURBO 

    function, under AUTO/COOL/FAN ONLY mode. Press again to cancel the 
    TURBO function, and the fan speed will change to pre-setting before.
    

Note:

 

 and 

 change: After insert the batteries, in the off state within 3 

    minutes, press the TURBO button for more than 5 seconds to switch the 
    Fahrenheit (

) or Celsius (

) degree display. 

5. 

DISPLAY:

 When the unit is ON, press the button, to switch off/on all lights 

    or LED display. And this function will be canceled when changing mode.

6. 

TIMER:

 Use the button to set the TIMER, or cancel the TIMER.

    

TIMER OFF:

 When the unit is ON, the timed OFF is programmed by 

    pressing TIMER button, the remote will display 6 hours pre-setting at first. 
    Set the rest time by pressing the button      or      until the needed rest time 
    display, then press TIMER button again to confirm.
    

TIMER ON:

 When the unit is OFF, the timed ON is programmed by pressing 

    TIMER button, the remote will display 6 hours pre-setting at first. Set the 
    rest time by pressing the button      or      until the needed rest time display, 
    then press TIMER button again to confirm. Later, the remote screen will keep 
    display [

TIMER

] icon.

  

  Note:

 When TIMER ON, it cannot select Sleep mode, but can pre-set Mode, 

    temperature, fan speed, MONEY SAVER. 

7. 

SLEEP: 

Press the SLEEP button, all of the display lights will turn off after a 

    while, but the Sleep light is always on. In SLEEP mode, the air conditioner 
    will automatically adjust the temperature and fan speed to make the room 
    more comfortable. The set temperature will automatically change every 30-
    60 minutes and at most change six times until the setting temperature is 81 
    or 82

 for cooling mode and 75 or 76

 for heating mode.. 

8. 

FAN

 

SPEED:

 Press the FAN SPEED button to choose the fan speed options. 

    You can choose Hi, Med, Lo or Auto speed in COOL or HEAT mode and 
    choose Hi, Med, Lo in FAN mode. When DRY mode, it is only Low fan speed.

9. 

MONEY SAVER:

 When the unit is in COOL mode, press the button to 

    MONEY SAVER function. In MONEY SAVER mode, the unit will turn off 
    once the room is cooled to the user set temperature. The unit will turn back 
    on when the room temperature rises above the user set temperature. Before 
    the compressor starts, the fan motor will run for a while, then it will stop for 
    a while, and will repeat to provide a much more comfortable feeling and 
    save energy.

10. 

Child Lock:

 pressing the button       or      for more than 2 seconds to lock 

      or unlock the remote controller. When locked, each function button is no 
      useful, and the lock icon will flash when press any button.

+

-

+

-

+ -

+ -

+ -

Содержание CEW08B11A

Страница 1: ...CCW06B10A CCW08B10A CCW10B10A CCW12B10A CEW08B11A CEW12B33A...

Страница 2: ...LIST INSTALLATION ASSEMBLY INSTRUCTIONS USING YOUR AIR CONDITIONER CARE AND CLEANING TROUBLESHOOTING ELECTRICAL REQUIREMENTS OPERATING YOUR AIR CONDITIONER THROUGH THE WALL INSTALLATION INSTRUCTIONS...

Страница 3: ...1...

Страница 4: ...ooling 10A time delay fuse or circuit breaker 12K heating 20A time delay fuse or circuit breaker 6K 8K 10K 12K Cooling 8K Heating 12K Heating 8K 12K cooling 8K heating 15A time delay fuse or circuit b...

Страница 5: ...Length Screws 3 4 Long Screws 5 8 Big Flat Head Bolt and Locknut 3 8 Short Screws Sill Angel Bracket 1 2 Small Flat Head Bolt and Locknut Support Bracket with R and L remark Chassis Lock 5 4 3 2 4 Ba...

Страница 6: ...The electrical outlet must be within reach of the power cord Window preparation ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER S MANUAL ARE THE PRESENTATION OF THE MANUFACTURE...

Страница 7: ...remove These screws will need tobe re installed prior to mounting the air conditioner 4 After removing the screws gently pull away the faceplate from the air conditioner cabinet REMOVE FRONT PANELAND...

Страница 8: ...ail from the top form of the packaging material as shown in FIG A 3 Align the hole in the top rail with those on the top of the unit as shown in FIG B 4 Secure the top rail to the unit with the 3 8 sc...

Страница 9: ...e the frame channel by making slight adjustments Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet Slide the panel all the way for both sides OFFSET STOOL SILL IN...

Страница 10: ...e chassis is firmly seated in the back of the cabinet 4 Insert all screws removed during window install ation and fasten then reattach the front face plate front panel and the air filter 5 If the wall...

Страница 11: ...pper and lower sashes as shown A storm window frame will not allow the air conditioner to tilt properly which in turn will keep it from draining properly To adjust for this attach a board or piece of...

Страница 12: ...the wall The opening and dimension of wooden frame is required as below IMPORTANT Frame Max Thickness Inside Frame Width Inside Frame Height The Maximum Wall thickness 8 9 10 225mm Inside Frame Heigh...

Страница 13: ...d 1 hour increment for 10hours or above The SET light will turn onwhile setting To cancel the set function press the TIMER button again liking the 5 Timer Button Cool Mode The cooling function allows...

Страница 14: ...press the Filter Check button When the Filter Check light is on it can turn off the light by pressing the Filter Check button After the fan motor works for 500 total hours the Filter Check light will...

Страница 15: ...until the needed rest time display then press TIMER button again to confirm TIMER ON When the unit is OFF the timed ON is programmed by pressing TIMER button the remote will display 6 hours pre settin...

Страница 16: ...14 FIG 15 15...

Страница 17: ...15...

Страница 18: ...16...

Страница 19: ......

Страница 20: ......

Отзывы: