background image

10

THROUGH-THE-WALL INSTALLATION INSTRUCTIONS - OPTIONAL

The case may be installed through-the-walll as optional.
Read completely, then follow step-by-step.
NOTE: Obtain all materials locally for mounting the air
conditioner through-the-wall.

Through-the-wall installation is not appropriate, if any of 
the side or top louvers of case is obstructed by the wall.

All side and top louvers in the case must project on the 
outdoor side of the wall.

The room side of the case must project into the room far 
enough to maximize the balance of the unit.

The case must be installed level from side to side and 
with a slight tilt from front to rear. Use a level, no more 
than a 1/2 bubble will be correct slant to the outside.

Lintel angle is required to support bricks or blocks 
above opening.

Flashing is required and should extend the length of the 
opening to ensure no inside cavity leakage occurs.

Building a wooden frame  is required when install the case
through-the-wall. The opening and dimension of wooden
frame is required as below.

IMPORTANT

Frame Max. Thickness

Inside Frame Width

Inside Frame Height

The Maximum
Wall thickness
8 9/10”(225mm)

Inside

Frame
Height

Frame

Thickness

8 9/10”( 225 mm)

1.Build a wooden frame into the wall opening and make 
   sure fasten securely, which is suitable to the WALL 
   OPENING REQUIREMENT.

2.Remove the air conditioner from the carton box and 
   take off the chassis as window mounting installation.

3.Place the cabinet into the wooden frame, and lock the 
   cabinet by the top rail hole and bottom chassis hole with
   1” long wood screws as shown,  from inside to outside.

4. Assemble the two Support Bracket with Sill Angle 
   Bracket to the cabinet against to the wooden frame as 
   window mounting installation instructions.

5. Assemble the chassis into the cabinet and fasten or 
   lock it, as window mounting installation instructions.

Sill angle bracket

Support bracket

Bolt and
Locknut

NOTE: The allowed maximum wall thickness is less than
8 9/10”. Otherwise, the wall will block the air inlet of
outdoor side, it will effect the normally operation of unit.

20”( 508 mm)

15-1/5”(385 mm)

Inside

Frame

Width

Содержание CEW08B11A

Страница 1: ...CCW06B10A CCW08B10A CCW10B10A CCW12B10A CEW08B11A CEW12B33A...

Страница 2: ...LIST INSTALLATION ASSEMBLY INSTRUCTIONS USING YOUR AIR CONDITIONER CARE AND CLEANING TROUBLESHOOTING ELECTRICAL REQUIREMENTS OPERATING YOUR AIR CONDITIONER THROUGH THE WALL INSTALLATION INSTRUCTIONS...

Страница 3: ...1...

Страница 4: ...ooling 10A time delay fuse or circuit breaker 12K heating 20A time delay fuse or circuit breaker 6K 8K 10K 12K Cooling 8K Heating 12K Heating 8K 12K cooling 8K heating 15A time delay fuse or circuit b...

Страница 5: ...Length Screws 3 4 Long Screws 5 8 Big Flat Head Bolt and Locknut 3 8 Short Screws Sill Angel Bracket 1 2 Small Flat Head Bolt and Locknut Support Bracket with R and L remark Chassis Lock 5 4 3 2 4 Ba...

Страница 6: ...The electrical outlet must be within reach of the power cord Window preparation ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER S MANUAL ARE THE PRESENTATION OF THE MANUFACTURE...

Страница 7: ...remove These screws will need tobe re installed prior to mounting the air conditioner 4 After removing the screws gently pull away the faceplate from the air conditioner cabinet REMOVE FRONT PANELAND...

Страница 8: ...ail from the top form of the packaging material as shown in FIG A 3 Align the hole in the top rail with those on the top of the unit as shown in FIG B 4 Secure the top rail to the unit with the 3 8 sc...

Страница 9: ...e the frame channel by making slight adjustments Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet Slide the panel all the way for both sides OFFSET STOOL SILL IN...

Страница 10: ...e chassis is firmly seated in the back of the cabinet 4 Insert all screws removed during window install ation and fasten then reattach the front face plate front panel and the air filter 5 If the wall...

Страница 11: ...pper and lower sashes as shown A storm window frame will not allow the air conditioner to tilt properly which in turn will keep it from draining properly To adjust for this attach a board or piece of...

Страница 12: ...the wall The opening and dimension of wooden frame is required as below IMPORTANT Frame Max Thickness Inside Frame Width Inside Frame Height The Maximum Wall thickness 8 9 10 225mm Inside Frame Heigh...

Страница 13: ...d 1 hour increment for 10hours or above The SET light will turn onwhile setting To cancel the set function press the TIMER button again liking the 5 Timer Button Cool Mode The cooling function allows...

Страница 14: ...press the Filter Check button When the Filter Check light is on it can turn off the light by pressing the Filter Check button After the fan motor works for 500 total hours the Filter Check light will...

Страница 15: ...until the needed rest time display then press TIMER button again to confirm TIMER ON When the unit is OFF the timed ON is programmed by pressing TIMER button the remote will display 6 hours pre settin...

Страница 16: ...14 FIG 15 15...

Страница 17: ...15...

Страница 18: ...16...

Страница 19: ......

Страница 20: ......

Отзывы: