STEP 4 - Line set installation

The Breeze connecting line set contains copper tubing that may kink if bent or formed incorrectly or repeatedly.

To avoid damaging your Breeze air conditioning system follow the 3 rules below throughout installation:
1)      DO NOT uncoil and recoil the connecting line set more than two times.

2)      DO NOT bend tubing in a radius smaller than 6”

3)      ALWAYS use the tube bending guide when making bends greater than 45°
Following these instructions is critical for proper installation and to avoid damage to the unit.  Damage to the 

connecting line due to improper installation will not be covered by the warranty.

4.1 Option 1 (3” hole pass through)

Completely uncoil the line set as straight as possible. Starting with the quick connect end of the line set, pass the entire 

length through the 3” hole. (Before installation break small plastic knockout on side of indoor unit for power cord to 

pass through-see Step 3, Figure 3.1).

4.2 Option 2 (SimpleSill

 window installation)

Uncoil enough of the line set to completely pass through the SimpleSill. Pre bend 

the line set using the enclosed template to match the desired shape as it passes 

through the SimpleSill. Place remaining coiled line set outside the window for 

later connection to the outdoor unit. Break full plastic knockout for line set to pass 

through the side of the indoor unit-see Step 3, Figure 3.2.

STEP 5 - Hang the indoor module on the wall bracket.  

Hang the module at the top first and rotate it down until the module is level with the 

wall.  (You may need to make adjustments to the connecting line to get the indoor 

module to mount cleanly)  The Breeze module is not designed to mount totally flush 

to the wall.  A space of 1/8” to 3/8” may be present between the module and the 

wall.

1. 

Be sure window sill is clean and free of dirt and debris. With the window raised, 

place bottom seal gasket (trimmed to window width) firmly against window sill 

(adhesive side down). Expand the SimpleSill™ 1” greater than the width of the win-

dow and install the securing pin. Place one end of the SimpleSill™ into the window 

opening so it is against the corner of the window frame and sill.  Raise the other 

side of the SimpleSill™ 6-9 inches (depending on window width) above the window 

sill. Next, press the raised side down until the SimpleSill™ is lodged securely into 

position. The SimpleSill™ end gaskets will conform to the window track shape. 

2. 

Reference Step 4.2 and pass the connecting line out the window and insert it into 

the connecting line form in the SimpleSill™.

3. 

Install top seal gasket to the bottom of the window so it will seal against the top of 

the SimpleSill.

4. 

Replace the pass through cover. 

5. 

Insert securing pins.

6. 

Lower window frame against SimpleSill compressing gasket. 

7. 

Depending on the type of window, install the appropriate security lock as recom-
mended by manufacturer.

Option 2: Window Installation Using Friedrich SimpleSill™

1

.

4

.

5.

STEP 5

The line set will sit in the recess of the 

back of the indoor unit when mounted.

Содержание Breeze BR1224W3A

Страница 1: ...tions for BR1224W3A 12000 24000 Btu Breeze A revolution in room cooling Friedrich Part No 96091001 Service Questions Contact Friedrich at 800 541 6645 Sales Inquiries Contact Sylvane at 800 934 9194 o...

Страница 2: ...module off of the ground 3 The fan should face away from the building 25 ft max 6 ft power cord NOTE Be sure to place your equipment with these limitations in mind 25 ft connecting line 6 ft power cor...

Страница 3: ...sold DO NOT PLUG IN INDOOR UNIT until you have completed the entire installation process CAUTION SHOCK HAZARD DO NOT PLUG IN indoor unit until all installation work is completed Connect to a single de...

Страница 4: ...red hole loca tion for pipes ducts electrical conductors and struc tural elements Relocate indoor unit mounting location as necessary to avoid interference Using a 3 hole saw drill hole through wall f...

Страница 5: ...odule on the wall bracket Hang the module at the top first and rotate it down until the module is level with the wall You may need to make adjustments to the connecting line to get the indoor module t...

Страница 6: ...sing enclosed 8 x 3 4 screw located on the top flange of the quick connect cover All Covers must be in place to operate unit SHOCK HAZARD exists without electrical access cover Cover cannot be install...

Страница 7: ...at removes the moisture collected from the indoor module The hose must be located in an appropriate location for drainage Because the hose relies on gravity to drain it is important that the hose only...

Страница 8: ...rn on the AUTO AIR SWEEP function or to set the desired angle of the airflow Airflow angle is reset each time power is turned off 8 EXTEND When on will be displayed In Cooling and Dry mode this will a...