STEP 1 - Determine how you will connect the indoor and outdoor modules.
There are two options available:
OPTION 1 is to drill a 3” hole through the wall to pass
the connecting line through.
OPTION 2 is to use the Friedrich SimpleSill™ kit to pass
the connecting pipe through the window. The Simple-
Sill™ is an optional accessory available where Breeze
is sold.
DO NOT PLUG IN INDOOR UNIT until you have
completed the entire installation process.
CAUTION
SHOCK HAZARD - DO NOT PLUG-IN indoor unit until all installation work is completed!
Connect to a single dedicated circuit sized for the load.
DO NOT kink or bend refrigeration line-set less than 3” radius – A connecting line bending guide is provided.
Line-set is under high pressure – DO NOT Puncture line-set.
DO NOT Heat line-set.
Always follow all local and national codes when installing equipment. Obtain the help of trained, skilled
worker where necessary.