6
A ‘beep’ sound is heard in learn mode…
¬
●
The push you are programming has already been learnt by the chime.
¬
●
If you want to change the icon associated with the push, use the un-learn procedure, then
programme the push again.
Two ‘beep’ sounds are heard after the normal chime sound…
¬
●
This indicates a low battery in the bell push that activated the chime. Fit a new battery, type CR2032.
When the bell push is operated, the amber confidence light does not turn on, or is only
on for a short time…
¬
●
In normal operation, the amber light will turn on for 1 second. When the battery is weak,
the light will only turn on for a short time. Fit a new battery, type CR2032.
The chime does not work…
●
Check that the batteries are the correct type, LR6 ‘AA’ cells.
Only use alkaline batteries.
●
Check that the batteries are fitted correctly.
●
The chime could be out of range of the bell push. Try the chime in a different location.
●
The chime might not have learnt the identity of the bell push. Follow the programming procedure.
The chime does not sound…
●
Check that the volume control is not at the minimum setting.
Range is reduced…
●
Metal structures, including uPVC door frames can reduce the range of the product.
Avoid mounting the push or chime on or near metal structures.
●
Other equipment can cause radio interference that affects your chime.
●
Walls and ceilings will reduce the range.
●
Weak batteries will reduce range. Replace every 12 –18 months. In cold conditions (below 5ºC),
batteries may need to be replaced more often.
Troubleshooting
Содержание D913 Libra +100m
Страница 34: ...33 34 35 36 37 39 39 40 100 RUSSIAN...
Страница 35: ...34 Libra 100 Friedland CR2032 2 2 2 4 6 3 x LR6 AA...
Страница 36: ...35 1 A 1 CR2032 2 2 CR2023 5 3 LR6 AA 3 B 4...
Страница 37: ...36 C 5 C 5 3 1 3 3...
Страница 38: ...37 _ 7 7 6 6...
Страница 39: ...38 CR2032 1 CR2032 LR6 AA...