Art.no Type

Power*

1

 

 

[W]

Airflow

 

 

[m³/h]

Sound 

level*

2

 

[dB(A)]

Humidity 

range 

[% RH]

Temp. 

range 

[°C]

Voltage 

 

[V]

Amperage 

 

[A]

Weight 

 

[kg]

247275

SUN30

660

200/280

47/51

30-100

8-32

230V~

2,9

18,5

1. Timer (button, 1-24 hours)
2. Timer indicator (LED)
3. 

Humidity selection button

4. 

Humidity indicator (LED) 

5. Full tank indicator (LED) 
6. Low speed indicator (LED)
7. Fan speed
8. 

High speed indicator (LED)

9. ON/OFF (power) indicator (LED)
10. ON/OFF button
11. Display (shows current humidity)

1

2

3

4

5

6

7

8

9

10

11

Operating hour meter 

•  The operating hour meter counts the 

compressor operating time.

• 

The 5 first digits shows the operating time in 

hours.

•  The operating hour meter will count-on 

continuously and never reset back to "zero". 

Operation - settings 

 

Start up

Plug the unit into a 230V earthed socket. 

Press the ON/OFF button to turn on the unit. 

The dehumidifier will start to work in CONT 

mode (continuous dehumidification). If the 

dehumidifier is not turned off by the ON/OFF 

button or has been turned off for at least 3 

minutes, the start of the compressor will be 

delayed for 3 minutes.  

To turn off the unit, press the ON/OFF button 

again.  

 

Setting of fan speed (low/high). 

Press the SPEED button to select the fan 

speed, high or low. High speed increases 

dehumidification.  

 

Setting desired humidity

Press button HUM to set the humidity: 

continuous dehumidification, 40%, 50%, 60% or 

70%. When the current humidity is below 35%, 

the display will show ‘LO’ and if the current 

humidity is over 95%, it will show ‘HI’. If the fan 

speed HI is selected, it will change to LO when 

the compressor stops and change to HI again 

when the compressor starts. 

 

Timer function 

When the Timer button is pressed, its LED (2) 

lights up. Press the Timer button to set the time 

of operation, between 0 and 24 hours. The time 

increases by one hour with each press of the 

button. The set time will flash before the display 

returns to show humidity. To see the remaining 

time, press the Timer button again. The timer is 

activated as long as its LED (2) is lit. The unit will 

be on continuous dehumidification if no time is 

set. 

Содержание Sunnan SUN30

Страница 1: ...Sunnan SUN30 Original instructions 2 EN 9 SE 15 NO 21 FR 28 DE 35 NL 42 ES 49 PL 56 RU 63 FI 69 DK ...

Страница 2: ...cuate all persons from the premises ventilate the premises and contact the local fire department to advise them that a propane leak has occurred Do not let any persons back into the premises until the qualified service technician has arrived and that technician advises that it is safe to return No open flames cigarettes or other possible sources of ignition should be used inside or in the vicinity...

Страница 3: ... a floor area larger than 4 m2 Compliance with national gas regulations shall be observed Keep any required ventilation openings clear of obstruction Warning Failure to abide by this warning could result in an explosion death injury and property damage Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredit...

Страница 4: ...2 dB A Humidity range RH Temp range C Voltage V Amperage A Weight kg 247275 SUN30 660 200 280 47 51 30 100 8 32 230V 2 9 18 5 At 30 C 80 RH At 20 C 60 RH Water tank capacity 30 13 6 2 l Capacity liters day 1 2 3 4 5 6 1 Handle 2 Control panel 3 Operating hour meter 4 Air filter 5 Water tank 6 Adapter for continous drain Placed in the water tank 528 mm 327 mm 337 mm ...

Страница 5: ...tart of the compressor will be delayed for 3 minutes To turn off the unit press the ON OFF button again Setting of fan speed low high Press the SPEED button to select the fan speed high or low High speed increases dehumidification Setting desired humidity Press button HUM to set the humidity continuous dehumidification 40 50 60 or 70 When the current humidity is below 35 the display will show LO a...

Страница 6: ...ositioned correctly Continuous drainage When the dehumidifier is operated at high temperatures and high humidity levels the water tank will require more frequent drainage In this situation it may be more convenient to set the unit up for continuous drainage with the following procedure 1 Pull out the water tank 2 Connect the drain hole inside the unit with the supplied adapter for continuous drain...

Страница 7: ...g from the socket and empty the tank let the tank and the dehumidifier dry completely this may take a couple of days 2 Clean the filter 3 Check that the dehumidifier is clean and in good condition before the storage 4 Protect the unit with a sheet of plastic 5 Store the dehumidifier in a dust free location out of direct sunlight Storage of several dehumidifiers NOTE A maximum of two units can be p...

Страница 8: ...e unit Make sure the air inlet and outlet are not obstructed The drain hole under the evaporator is clogged Clean the drain hole The continuous drainage is not working correctly Check that the hose is installed correctly and that the water drains away freely The display does not show the set humidity This is normal The display shows the current humidity not the set point The set humidity is shown ...