SUN30

4

EN

*

1

) Conditions: 30°C 80% RH, 24 h. 

*

2

) Distance to unit 3 meters. 

Components

Technical specifications 

SUN30 R290 (IPX4)

Art.no Type

Power*

1

 

 

[W]

Airflow

 

 

[m³/h]

Sound 

level*

2

 

[dB(A)]

Humidity 

range 

[% RH]

Temp. 

range 

[°C]

Voltage 

 

[V]

Amperage 

 

[A]

Weight 

 

[kg]

247275

SUN30

660

200/280

47/51

30-100

8-32

230V~

2,9

18,5

At 30 °C

80% RH

At 20 °C

60% RH

Water tank  

capacity 

30

13

6,2 l

Capacity (liters/day)

1

2
3

4

5

6

1. 

Handle

2. Control panel
3. Operating hour meter
4. 

Air filter

5. Water tank
6. Adapter for continous drain. 

Placed in the water tank.

528 mm

327 mm

337 mm

Содержание Sunnan SUN30

Страница 1: ...Sunnan SUN30 Original instructions 2 EN 9 SE 15 NO 21 FR 28 DE 35 NL 42 ES 49 PL 56 RU 63 FI 69 DK ...

Страница 2: ...cuate all persons from the premises ventilate the premises and contact the local fire department to advise them that a propane leak has occurred Do not let any persons back into the premises until the qualified service technician has arrived and that technician advises that it is safe to return No open flames cigarettes or other possible sources of ignition should be used inside or in the vicinity...

Страница 3: ... a floor area larger than 4 m2 Compliance with national gas regulations shall be observed Keep any required ventilation openings clear of obstruction Warning Failure to abide by this warning could result in an explosion death injury and property damage Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredit...

Страница 4: ...2 dB A Humidity range RH Temp range C Voltage V Amperage A Weight kg 247275 SUN30 660 200 280 47 51 30 100 8 32 230V 2 9 18 5 At 30 C 80 RH At 20 C 60 RH Water tank capacity 30 13 6 2 l Capacity liters day 1 2 3 4 5 6 1 Handle 2 Control panel 3 Operating hour meter 4 Air filter 5 Water tank 6 Adapter for continous drain Placed in the water tank 528 mm 327 mm 337 mm ...

Страница 5: ...tart of the compressor will be delayed for 3 minutes To turn off the unit press the ON OFF button again Setting of fan speed low high Press the SPEED button to select the fan speed high or low High speed increases dehumidification Setting desired humidity Press button HUM to set the humidity continuous dehumidification 40 50 60 or 70 When the current humidity is below 35 the display will show LO a...

Страница 6: ...ositioned correctly Continuous drainage When the dehumidifier is operated at high temperatures and high humidity levels the water tank will require more frequent drainage In this situation it may be more convenient to set the unit up for continuous drainage with the following procedure 1 Pull out the water tank 2 Connect the drain hole inside the unit with the supplied adapter for continuous drain...

Страница 7: ...g from the socket and empty the tank let the tank and the dehumidifier dry completely this may take a couple of days 2 Clean the filter 3 Check that the dehumidifier is clean and in good condition before the storage 4 Protect the unit with a sheet of plastic 5 Store the dehumidifier in a dust free location out of direct sunlight Storage of several dehumidifiers NOTE A maximum of two units can be p...

Страница 8: ...e unit Make sure the air inlet and outlet are not obstructed The drain hole under the evaporator is clogged Clean the drain hole The continuous drainage is not working correctly Check that the hose is installed correctly and that the water drains away freely The display does not show the set humidity This is normal The display shows the current humidity not the set point The set humidity is shown ...

Страница 9: ...ce Frico AB Tel 46 31 336 86 00 Industrivägen 41 SE 433 61 Sävedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico net 2022 05 06 HH CH ...