Frico Soloclim vertical SCV21DCI Скачать руководство пользователя страница 6

Soloclim Vertical - Utilisation

6

EN

Key/Display

Operation

Switching the appliance on and off

It is possible to switch the appliance on or off (stand-by) by pressing the specific button. The control 
system of the appliance is equipped with a memory, so settings will not be lost if the appliance is 
switched off or in the power supply is cut. This key is used to activate or deactivate the appliance for 
short periods of time. 

 

In case of long periods of inactivity, the appliance must be deactivated by disconnecting either 

the main switch or the plug from the socket.

Well-being button (economic automatic mode) 

By choosing this mode on the appliance, it sets the best level of comfort in the room. The conditioner 
selects the mode automatically (cooling or heating) according to the temperature set and ventilation 
speed according to the temperature of the room. 

 

Cooling only mode

In this mode, the appliance dehumidifies and cools the room. 

   

   

It is possible to set the desired temperature between 16 and 31°C and, if this temperature is lower than 
the room temperature, the compressor starts up after three minutes (maximum) and the appliance 
starts dispensing cool air, maintaining ventilation active even if the setpoint has been reached.

   

 

Dehumidification only mode

In this mode, the appliance dehumidifies the room. Selecting this mode is useful during mid-seasons, 
i.e. on days (e.g. rainy ones) when the temperature is pleasant, but excess humidity causes discomfort. 
This mode ignores both room temperature and ventilation speed settings.The latter is always set to a 
minimum. It is normal for the appliance to work intermittently.

 

Ventilation only mode

By selecting this function, the compressor is never activated and the appliance does not affect either 
room temperature or humidity. it is possible to choose the speed of the fan

 

Heating only mode

In this mode, the appliance heats the room. 

 

Set on heating only mode, the appliance periodically defrosts the evaporator coil, if necessary. 

During this phase, the conditioner does not dispense warm air, even if its internal components are on, 
except for the room fan.

   

   

It is possible to set the desired temperature between 16 and 31°C and, if such temperature is higher 
than the room temperature, the compressor starts up after three minutes (maximum) and the appliance 
starts dispensing warm air.

   

 

Nocturnal well-being button

While the appliance is on in the selected cooling or heating mode, it is possible to choose different 
functions by pressing the button in order to maximise noise reduction, energy saving and nocturnal 
well-being regulation. 
In this mode, ventilation is set on minimum speed.
This mode should be activated right before going to sleep.
•  In cooling mode, the set temperature is increased by 1°C after one hour and by another degree after 

two.  After the second hour, the temperature is no longer changed and, after six hours, the appliance 
is put in stand-by. 

•  In heating mode, the set temperature is lowered by 1°C after one hour and by another degree after 

two. After the second hour, the temperature is no longer changed and, after six hours, the appliance 
is put in stand-by.

This function is not available for dehumidification only, ventilation only and economic automatic 
modes and can be excluded any time (ideally once awake) by pressing the button again. 
If the Timer has also been set, the appliance will turn off at the set time. 

Содержание Soloclim vertical SCV21DCI

Страница 1: ...Soloclim vertical EN Installation manual...

Страница 2: ...tion indication on the labels of energy related products 2010 30 EU ErP Directive 2009 125 EC and regulation 2012 20EC The pictograms in the next chapter provide the necessary information for correct...

Страница 3: ...e with touch screen display and remote control 4 Description of operation 5 Setting cool only or heat only modes 8 Brightness regulation 8 Touch screen dsplay key lock 8 Hotel function 8 Suggestions f...

Страница 4: ...on working but it does not dispense warm air to the room This phase can last from 3 up to maximum 10 minutes The appliance must not be installed in rooms where explosive gases develop or where there...

Страница 5: ...g the room If the temperature is set too low or too high not only it is unhealthy but it is also an unnecessary waste of energy EN Description of operations It is possible to select the various modes...

Страница 6: ...ppliance to work intermittently Ventilation only mode By selecting this function the compressor is never activated and the appliance does not affect either room temperature or humidity it is possible...

Страница 7: ...and the temperature set This is not possible in humidification only or nocturnal well being mode where the appliance can only operate at a low speed Setting the Timer function The appliance allows th...

Страница 8: ...he settable set range is reduced from 22 to 28 in cooling mode and from 16 to 24 in heating mode The display brightness sensor can be disabled leaving the maximum brightness at all times by pressing a...

Страница 9: ...the operating logic of the unit so as to protect the compressor from frequent activations During operation in heating mode the warm air is delivered a few minutes after the activation of the compress...

Страница 10: ...lowing instructions below Cover large windows exposed to sunlight with curtains or with external maskings blinds porches reflecting films etc The air conditioned room must remain closed for as long as...

Страница 11: ...B 8 C Vertical SCV21DCI SCV23DCI Item number 999925 999926 Cooling capacity 1 kW 2 04 2 35 Dual Power maximum cooling output kW 2 6 3 1 Minimum cooling output kW 0 8 0 9 Heating output 2 kW 2 10 2 36...

Страница 12: ...to the concentration of impurities in the air or when you wish to start up the appliance after a period of inactivity The filter is located in the top part of the appliance To extract the filters ope...

Страница 13: ...al 2021 06 04 CH Main o ce Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local conta...

Отзывы: