Technical specifications 

Please read data plate to obtain the technical data listed 
below. 

Power supply voltage 

Maximum absorbed power 

Maximum absorbed current 

Amount of refrigerant gas 

Casing protection rating 

(1) (2) Conditions according to standard EN 14511. 
(4) Indoor sound pressure measured in anecoic room. 
(5) Indoor sound power measured according to standard EN 12102. 
(6) Energy efficiency according to Directive 626/2011.

Max work conditions

Cooling temperature, (indoor/outdoor, DB) ; minimum 18 °C/-5 °C, maximum 32 °C/43 °C
Heating temperature, (indoor/outdoor, DB) ; minimum 5 °C/-10 °C, maximum 25 °C/18 °C

Test conditions  

 

 

Room temperature    

Outdoor temperature

Test conditions, cooling (1) 

 

DB 27 °C - WB 19 °C   

DB 35 °C - WB 24 °C

Test conditions, heating (2) 

 

DB 20 °C - WB 15 °C   

DB 7 °C - WB 6 °C

Test conditions, heating (3) 

 

DB 20 °C - WB 15 °C   

DB -7 °C - WB -8 °C

Vertical

SCV21DCI

SCV23DCI

Item number

999925

999926

Cooling capacity (1)

kW

2,04

2,35

Dual Power maximum cooling output

kW

2,6

3,1

Minimum cooling output

kW

0,8

0,9

Heating output (2)

kW

2,10

2,36

Heating output -7°C (3)

kW

0,98

1,11

Additional output by electrical resistance 

kW

-

-

Dual Power maximum heating output

kW

2,64

3,05

Minimum heating output

kW

0,7

0,8

Power input cooling (1)

W

750

855

Power input heating (2)

W

675

770

Dehumidifying capacity

l/h

0,8

0,9

Supply voltage 

V-F-Hz

230-1-50

230-1-50

EER

W/W

2,72

2,75

COP

W/W

3,10

3,15

Energy efficiency in cooling (6)

A

A

Energy efficiency in heating (6)

A

A

Fan speed in/out 

Nr.

3

3

Maximum air flow in/out 

m

3

/h

380/460

400/480

Middle air flow in/out 

m

3

/h

310/380

320/390

Minimum air flow in/out  

m

3

/h

260/330

270/340

Dimensions (LxHxD)

mm

500x1400x185

500x1400x185

Weight 

Kg

53

53

Minimum/maximum sound level (4)

dB (A)

26/39

27/41

Minimum/maximum sound power LWA (5)

dB (A)

44/57

45/58

Diameter of wall holes

mm

162

162

Interaxis distance between wall holes 

mm

293

293

Refrigerant gaz

R-410A

R-410A

Содержание Soloclim vertical SCV21DCI

Страница 1: ...Soloclim vertical EN Installation manual...

Страница 2: ...tion indication on the labels of energy related products 2010 30 EU ErP Directive 2009 125 EC and regulation 2012 20EC The pictograms in the next chapter provide the necessary information for correct...

Страница 3: ...e with touch screen display and remote control 4 Description of operation 5 Setting cool only or heat only modes 8 Brightness regulation 8 Touch screen dsplay key lock 8 Hotel function 8 Suggestions f...

Страница 4: ...on working but it does not dispense warm air to the room This phase can last from 3 up to maximum 10 minutes The appliance must not be installed in rooms where explosive gases develop or where there...

Страница 5: ...g the room If the temperature is set too low or too high not only it is unhealthy but it is also an unnecessary waste of energy EN Description of operations It is possible to select the various modes...

Страница 6: ...ppliance to work intermittently Ventilation only mode By selecting this function the compressor is never activated and the appliance does not affect either room temperature or humidity it is possible...

Страница 7: ...and the temperature set This is not possible in humidification only or nocturnal well being mode where the appliance can only operate at a low speed Setting the Timer function The appliance allows th...

Страница 8: ...he settable set range is reduced from 22 to 28 in cooling mode and from 16 to 24 in heating mode The display brightness sensor can be disabled leaving the maximum brightness at all times by pressing a...

Страница 9: ...the operating logic of the unit so as to protect the compressor from frequent activations During operation in heating mode the warm air is delivered a few minutes after the activation of the compress...

Страница 10: ...lowing instructions below Cover large windows exposed to sunlight with curtains or with external maskings blinds porches reflecting films etc The air conditioned room must remain closed for as long as...

Страница 11: ...B 8 C Vertical SCV21DCI SCV23DCI Item number 999925 999926 Cooling capacity 1 kW 2 04 2 35 Dual Power maximum cooling output kW 2 6 3 1 Minimum cooling output kW 0 8 0 9 Heating output 2 kW 2 10 2 36...

Страница 12: ...to the concentration of impurities in the air or when you wish to start up the appliance after a period of inactivity The filter is located in the top part of the appliance To extract the filters ope...

Страница 13: ...al 2021 06 04 CH Main o ce Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local conta...

Отзывы: