Frico Soloclim vertical SCV21DCI Скачать руководство пользователя страница 1

Soloclim vertical

EN  

Installation manual

Содержание Soloclim vertical SCV21DCI

Страница 1: ...Soloclim vertical EN Installation manual...

Страница 2: ...tion indication on the labels of energy related products 2010 30 EU ErP Directive 2009 125 EC and regulation 2012 20EC The pictograms in the next chapter provide the necessary information for correct...

Страница 3: ...e with touch screen display and remote control 4 Description of operation 5 Setting cool only or heat only modes 8 Brightness regulation 8 Touch screen dsplay key lock 8 Hotel function 8 Suggestions f...

Страница 4: ...on working but it does not dispense warm air to the room This phase can last from 3 up to maximum 10 minutes The appliance must not be installed in rooms where explosive gases develop or where there...

Страница 5: ...g the room If the temperature is set too low or too high not only it is unhealthy but it is also an unnecessary waste of energy EN Description of operations It is possible to select the various modes...

Страница 6: ...ppliance to work intermittently Ventilation only mode By selecting this function the compressor is never activated and the appliance does not affect either room temperature or humidity it is possible...

Страница 7: ...and the temperature set This is not possible in humidification only or nocturnal well being mode where the appliance can only operate at a low speed Setting the Timer function The appliance allows th...

Страница 8: ...he settable set range is reduced from 22 to 28 in cooling mode and from 16 to 24 in heating mode The display brightness sensor can be disabled leaving the maximum brightness at all times by pressing a...

Страница 9: ...the operating logic of the unit so as to protect the compressor from frequent activations During operation in heating mode the warm air is delivered a few minutes after the activation of the compress...

Страница 10: ...lowing instructions below Cover large windows exposed to sunlight with curtains or with external maskings blinds porches reflecting films etc The air conditioned room must remain closed for as long as...

Страница 11: ...B 8 C Vertical SCV21DCI SCV23DCI Item number 999925 999926 Cooling capacity 1 kW 2 04 2 35 Dual Power maximum cooling output kW 2 6 3 1 Minimum cooling output kW 0 8 0 9 Heating output 2 kW 2 10 2 36...

Страница 12: ...to the concentration of impurities in the air or when you wish to start up the appliance after a period of inactivity The filter is located in the top part of the appliance To extract the filters ope...

Страница 13: ...al 2021 06 04 CH Main o ce Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local conta...