background image

.

... 19

GB  

.

... 2

SE  

For more languages, please see www.frico.se

For wiring diagram, please see p.71-73

SIRe Competent Air Curtains

Water

With quick guide

SIReAC

Original instructions

.

... 54

FR  

.

... 36

DE  

Содержание SIReAC

Страница 1: ...19 GB 2 SE For more languages please see www frico se For wiring diagram please see p 71 73 SIRe Competent Air Curtains Water With quick guide SIReAC Original instructions 54 FR 36 DE...

Страница 2: ...ReC1X with RJ12 modular cables In SIReB1 X the unit is also connected further with RJ12 modular cable if several units are to be connected in parallel If external room temperature sensor SIReRTX optio...

Страница 3: ...t open for longer periods 24 25 Function description of current stage 25 26 Control unit SIReUA1 Overview 27 Main menu Current settings 28 Temp settings 28 Fan control 28 Summer Winter 28 System on of...

Страница 4: ...rts SIReAC Integrated in the air curtain Wall unit cover SIReIT internal temperature sensors SIReDC magnetic door contact Type Description HxWxD mm L m SIReUA1 Control unit Competent and Advanced 120x...

Страница 5: ...maximum of 300 m Type RSK no E no Description HxWxD mm L m SIReRTX 673 09 22 87 510 12 External room temperature sensor 70x33x23 SIReUR 673 09 21 87 510 11 Kit for recessed installation 114x70x50 SIR...

Страница 6: ...ow Connection VOS15LF 673 09 35 On off Low DN15 VOS15NF 673 09 36 On off Normal DN15 VOS20 673 09 37 On off Normal DN20 VOS25 673 09 38 On off Normal DN25 VOSP15LF 673 09 43 Pressure independent Low D...

Страница 7: ...xternal room temperature sensor SIReRTX option When the door is closed over run When heat has been connected and the door has been closed high speed mode remains to cool the unit from any excess heat...

Страница 8: ...e current settings the current stage increases by 1 step If the room temperature is more than 2 degrees above the current setting the current stage decreases by 1 step Summer If summer mode is selecte...

Страница 9: ...nt stage for units with 5 fan controls Current stage Fan Heating 0 0 OFF 1 1 OFF 2 2 OFF 3 2 ON 4 3 ON 5 3 ON Current stage Fan Heating 0 0 OFF 1 1 OFF 2 2 OFF 3 2 ON 4 3 ON 5 3 ON 6 4 ON 7 5 ON 8 5 O...

Страница 10: ...ating step door status and day night mode or Off when the week program is used Forward arrow Confirm selection and proceed Rotary dial Scroll between alternatives Back arrow Go back After three minute...

Страница 11: ...menu Fan control Factory setting High speed limit 3 resp 5 1 3 resp 1 5 Speed closed door 1 Off 3 resp Off 4 Summer Winter To permit or block heating Heating is permitted in winter mode Summer mode is...

Страница 12: ...Day 4 16 00 Night Remove single Remove all Reset all Remove program Change program Mon Tue Wed Thu Fri Sat Sun 1 08 00 Day 2 18 00 Night 3 10 00 Day 4 16 00 Night Installer menu To enter the Installe...

Страница 13: ...ttings Door over run Over run mode High speed over run Low speed over run Installer menu Fan settings Door over run Door over run Door mode Installer menu Fan settings Settings fan Make settings for f...

Страница 14: ...sor displays the wrong values these can be calibrated Some display errors may occur but this is primarily due to the location cold hot surfaces etc The value or adds to or subtracts from the measured...

Страница 15: ...al control General settings Support menu Installer menu Set date Set time Set language Installer menu General settings Set temp unit Function test User reset Installer menu General settings Execute us...

Страница 16: ...nal sensor The over heating protection is intended to restrict the exhaust temperature to 40 C At 40 C the valve actuator closes If the unit cools below 35 C heating is automatically reengaged If the...

Страница 17: ...ectified SIReUA1 must be replaced Table Error codes Alarm Cause Action A1 Motor alarm Thermal switch has deployed One or several motors have overheated Only units with withdrawn thermal switches Check...

Страница 18: ...menu External control External On Off On External night reduction on off potential free switch Closes to activate the night reduction function Always active Alarm outgoing BMS potential free switch m...

Страница 19: ...TEMP ON OFF potential free contact EXTERNAL ALARM IN potential free contact EXTERNAL RPM 0 10V DC IN EXTERNAL ON OFF 5 30V AC DC ALARM OUT BMS potential free contact max 3A 230V 7 8 9 10 1112 15 1617...

Страница 20: ...ial free contact EXTERNAL ALARM IN potential free contact EXTERNAL RPM 0 10V DC IN EXTERNAL ON OFF 5 30V AC DC ALARM OUT BMS potential free contact max 3A 230V 7 8 9 10 1112 15 161718 19 20 COM 1 COM...

Страница 21: ...L N L PE ACTUATOR SUPPLY SIReSD230 SIReSD230 SIReSD230 SIReRTX optional SIReUA1 EXTERNAL SETBACK TEMP ON OFF potential free contact EXTERNAL ALARM IN potential free contact EXTERNAL RPM 0 10V DC IN E...

Страница 22: ...B Tel 46 31 336 86 00 Box 102 Fax 46 31 26 28 25 SE 433 22 Partille mailbox frico se Sweden www frico se For latest updated information and information about your local contact www frico se Art no E44...

Отзывы: