![FRIATEC friatools series Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/friatec/friatools-series/friatools-series_operating-instructions-manual_2332094018.webp)
Update/Stand: 11.2017
18
EN
2.6
Generator operation
NOTICE
Only those generators must be used that have been designed for industrial
use on building sites. The operating instructions for the generator must be
observed!
The use of generators must comply with DVGW work sheet GW308, VDE 0100
Part 728, and the specifications and guidelines applying in the country of use.
NOTICE
The vaccum pumpe can be operated together with a FRIAMAT fusion unit at
the same generator. The manufacturer‘s instructions must be observed for the
common use with other electrical consumers!
2.7
Opening the device
WARNING
Electric shock from live parts! Danger of death!
• Never open the vacuum pump when it is supplied with operating voltage!
• The vacuum pump may be opened only by specialised personnel from an
authorised FRIATEC service station!
3.
Technical details
Technical details*
Vacuum pump 230V
Vacuum pump 110V
Order Ref.
613827
613828
Input voltage range
230V
110V
Frequency range
50/60Hz
50/60Hz
Ultimate vacuum
approx. -900 mbar
approx. -900 mbar
Protection Class
IP 54
IP 54
Operating temperature range
-10°C bis +45°C
-10°C bis +45°C
Dimensions (W x D x H)
approx. 345 x 215 x 315 mm
approx. 345 x 215 x 315 mm
Weight
approx. 9,5 kg
approx. 9,5 kg
*: Specifications subject to change.