1.4

Sources of danger

- Replace damaged mains lead and extension

cables immediately. 

- Do not remove or disable safety devices. 
- Rectify known faults immediately. 
- Do not leave your FRIAMAT

®

fusion unit un at tend -

ed. 

- Keep away from flammable liquids/gases. 
- Do not operate in EX environment. 

1.5

Authorised users

Only trained personnel may work using your
 FRIAMAT

®

fusion unit. The user is responsible for

third parties in the work area. The user must:

- make accessible the operating instructions to the

operator and 

- ensure that he or she has read and understood

them.

1.6

Dangers from electric power

- Do not use any damaged connecting cables. 
- Check connection cable for any damage. 
- Pull out the plug prior to any maintenance or

 service tasks! 

- Allow any service and repairs to be carried out

only at authorised service stations! 

- Connect fusion units of the FRIAMAT

®

range only

to supply voltage as given on type plate.

DANGER!

Distribution points on the construction site:
observe regulation on circuit breakers!

Outdoors (on construction sites) receptacles must
be fitted with fault-current circuit breakers. When
using generators, the DVGW worksheet GW308 and
the VDE 0100 Part 728 need to be observed. The
required generator nominal output depends on the
output required by the largest fitting to be used, on
connection conditions, ambient conditions and the
actual generator type (its control characteristics). As
the generators from different model ranges often
display very different control characteristics, the
 suitability of a generator cannot be guaranteed by
the specified rated output alone.

FM_2427_2_GB_03_12.qxp:-  28.03.2012  9:28 Uhr  Seite 6

Содержание FRIAMAT GEO PRINT

Страница 1: ...Operating Instructions FRIAMAT FRIAMAT...

Страница 2: ...2 2 Operating principle 9 2 3 Technical data 10 2 4 Automatic activation of Service interval 11 2 5 Transport Storage Despatch 11 2 6 Setting up Connecting 11 2 7 Operating 12 3 Basic Fusion Procedure...

Страница 3: ...t of service 19 6 Operating faults 20 6 1 Errors when reading in the barcode 20 6 2 Overheating 20 6 3 Fusion interruption 20 6 4 Error messages Warning messages Info 20 7 Appendix 23 7 1 Recommended...

Страница 4: ...with regard to the health of the user your FRIAMAT fusion unit or other material goods of the operator the efficient operation of your FRIAMAT fusion unit Everybody involved with operating servicing...

Страница 5: ...83 and to ISO 13950 03 2007 The designated use also includes observation of all the advice in these operating instructions as well as the guidelines by DVGW Standards DVS UVV and local directives IMPO...

Страница 6: ...ior to any maintenance or service tasks Allow any service and repairs to be carried out only at authorised service stations Connect fusion units of the FRIAMAT range only to supply voltage as given on...

Страница 7: ...ess Your FRIAMAT fusion unit has been designed for input voltage of 190 250 volt When using an extension cable please ensure suffi cient cross section 2 5 mm2 up to 100 m Always roll out cable fully b...

Страница 8: ...rmed 2 signals fusion process completed 3 signals supply voltage too low too high 5 signals warning error refer to display 1 10 Emergencies In case of an emergency switch off main switch immediately t...

Страница 9: ...ble conti nuously measures the ambient temperature WARNING The temperature sensor for determining the ambient temperature is attached to the fusion cable at the reader wand cable near the reader wand...

Страница 10: ...uit and Cut Off Printer interface USB Connecting plug 4 0 mm yes Manual emergency yes programming Remote operating pass optional Operator pass no Supervisor pass no FRIATRACE no Documentation of fusio...

Страница 11: ...packing requires no specific skills nor does storage in the transport box The tempe rature range during storage is 20 C 70 C WARNING Always transport store inside aluminium trans port box 2 6 Setting...

Страница 12: ...be observed The same applies for fittings by other manufacturers IMPORTANT Roll out cables completely This applies to power cable fusion cable and extension cable if required The contact surfaces of t...

Страница 13: ...e fitting as a resistance check is carried out imme diately after reading in the barcode An error message will appear if there is non contact Please also ensure that the fusion plugs of your FRIAMAT f...

Страница 14: ...anufacturer please observe operating instructions by the appro priate fitting manufacturer Operating steps see also the visual description on the next page 1 Display shows PIPE PREPARED confirm if cor...

Страница 15: ...STOP The STOP button is red It cancels the fusion process is used to close submenus or indivi dual menus and stops the entering process without saving data Arrow buttons The arrow buttons are blue Th...

Страница 16: ...documentation is switched on and an initial set of data has been saved 4 3 1 Menu Transfer The guide button MENUE will take you to the menu Data with its submenu Transfer Your FRIAMAT geo print will...

Страница 17: ...nce you have deleted data it has been lost irrevocably The unit has an automatic back up function which may allow authorised FRIATEC service personnel to retrieve deleted data Please contact your loca...

Страница 18: ...bers have been entered using the arrow buttons you must confirm this by pressing the START button if you press the STOP button the process will be stopped without saving data 4 6 Menu Formatting Press...

Страница 19: ...ld be carried out once a year see list of authorised service points in section 7 2 Please include all connecting adapters for service checks WHAT WHEN WHO Cleaning the reader daily user wand and check...

Страница 20: ...nit cool down As the power consumption of different electrofusion fittings will vary there may be the option of fusing a different fitting 6 3 Fusion interruption If the fusion is interrupted because...

Страница 21: ...checks fitting 05 Fitting Current flow Check winding interrupted connection open circuit of fusion plug on fitting If okay replace the fitting and send in for checks 06 Voltage Non Contact outside per...

Страница 22: ...r Please contact failure maybe not FRIATEC suited for service hotline fusion work 49 0 621 486 1533 xy System Please contact error FRIATEC service hotline 49 0 621 486 1533 error messages with numbers...

Страница 23: ...vice date exceeded point Arrange for unit to be serviced 7 Appendix 7 1 Recommended accessories FRIATEC Memory Stick USB to transfer fusion data from fusion unit to PC Laptop option Remote control pas...

Страница 24: ...2427 2e 13 03 2012 FRIATEC Aktiengesellschaft Technical Plastics Division P O Box 71 02 61 D 68222 Mannheim Phone 49 621 486 1533 Fax 49 621 479196 www friatools com info friatools friatec de...

Отзывы: