12
2.7
Operating
WARNING!
Charring! Dirty contacts may char the plug.
Contact surfaces of fitting and fusion plug must be
clean
at all times
:
- Thoroughly remove any existing deposits.
- Protect plug from contamination, replace if
necessary.
- Check fusion plug and contact sockets of the
fitting for dirt before connecting.
3
Basic “Fusion” Procedure
3.1
Preparation
The relevant assembly instructions for the proper
processing of component parts of the FRIALEN
®
Geo product range and the FRIALEN
®
safety fittings
up to d75 are to be observed. The same applies for
fittings by other manufacturers.
IMPORTANT!
Roll out cables completely!
This applies to power cable, fusion cable, and
extension cable if required. The contact surfaces
of the fitting and the fusion plugs must be clean;
dirty contacts can cause overheating and char-
ring of the plug. If necessary carefully remove
any existing deposits.
Always protect plugs from contamination. If
there is evidence of a deposit which cannot be
completely removed, the fusion plugs must be
replaced.
- Prepare fitting and pipes for fusion in accordance
with assembly instructions.
- Ensure that the contact pins on the fitting are
accessible for connection of fusion plugs.
- Connect to power supply (mains or generator).