Step 15:

  It is important to perform the reset 

operation below before you use your My-Hite 
table for the first time.

FIRST TIME USE:

RESET OPERATION

1.  Lower the table to 24.5” by holding arrow down (V) button. Release button.

2. Press the arrow down (V) button again and hold till ASR shows on the display.

3. Release the button and the ASR will flash on the display

4. Hold the arrow down button again. Table will shift up and down slightly as it resets to 

24.5”.

SET MINIMUM HEIGHT

SET MAXIMUM HEIGHT

1.  Press the arrow down (V) button to get to desired minimum height. 

 

Note: the arrow down button must be the last button pressed to set the minimum height. You 
cannot press the arrow up button when trying to set the minimum height.

2. Hold “S” button till screen display flashes. Immediately press “S” button twice again.

3. Display will flash “000” and then show the set minimum height.

V

1. 

Press the arrow up (  ) button to get to desired maximum height. 

 

Note: the arrow up button must be the last button pressed to set the maximum height. You 
cannot press the arrow down button when trying to set the maximum height.

2. 

Hold “S” button till screen display flashes. Immediately press “S” button  
twice again.

3. 

Display will flash “999” and then show the set maximum height.

TO PROGRAM THE MEMORY CONTROL PANEL:

Adjust the table to the desired height, press the 

S

 key and one of the three preset 

buttons. This position is now saved. Once a preset button is pushed, the table will 
automatically move to the preset height. Repeat this procedure for each preset button.

TROUBLESHOOTING MY-HITE

Error code

Explanation

Cause

Solution

H01

Motor has 
overheated

Overuse

1. 

Let motor rest for 10 minutes.

2. 

Perform reset operation.

3. 

If problem persists 

contact Friant customer 

service

ERR,
ASR or 
RST (solid 
or flashing)

System is 
locked

Various Reasons

1. 

Remove plug from electrical outlet for 15 
seconds, then plug unit back in.

2. 

Perform reset operation.

3. 

If problem persists 

contact Friant customer 

service to replace control panel

No display

Control 
Panel has 
lost power

Disruption in 
power supply to 
base

1. 

Remove plug from electrical outlet for 15 
seconds, then plug unit back in.

2. 

Perform reset operation.

3. 

If problem persists 

contact Friant customer 

service to replace control panel.

E01, 
E02, or
E03

Excessive 
weight 
distribution

Too much 
weight (limit 
exceeded)

or

 

Other problem

1. 

Check that weight on table does not exceed 
limit.

2. 

Perform reset operation.

3. 

If problem persists 

contact Friant customer 

service to replace control panel

E07,
E08, or
E09

Signal 
Interruption 

Signal is 
interrupted 
between leg 
and computer

1. 

Perform reset operation. 

2. 

If problem persists 

contact Friant customer 

service

CLEAR MAXIMUM & MINIMUM HEIGHT

1.  Table can be at 

ANY HEIGHT

 but 

NOT

 the minimum or maximum.

2. Hold “S” til display flashes. Release button.

3. Press “S” slowly, multiple times - until “555” shows on display. 

Note: Display will show other codes, continue to press “S” until “555” shows.

4. Display will then show table height and can now move to any height between 24.5” and 

50.1”. 

NOTE : 

If 

you cannot lower the table to the 24.5” height to perform reset operation, 

you may need to clear out the maximum and minimum height (See instructions 
below). Once completed, please return to the Reset Operation instructions.

SPECIAL CLEAR  MINIMUM & MAXIMUM HEIGHT

1.  Following is a special reset procedure when minimum and maximum height is set 

within 1”

 of each other:

2. Unplug unit for 10 minutes

3. Connect unit to power take care not to touch up or down arrows

4. Hold S button until it flashes

5. Let go and press S button 6 times in a row

6. 555 will show up on the display, minimum and maximum heights are now cleared.

July 2019

1980 West Avenue, 140th, San Leandro CA 94577   TEL: 510.535.5113  FAX: 510.535.5237   http://www.

friant.com

Содержание FCNAHBC

Страница 1: ...MY HITE ADJUSTABLE TABLE Model Number FCNAHBC Corner C Leg Base Please Read Instructions Before Use ASSEMBLY INSTRUCTIONS ALL WORKSTYLES WELCOME...

Страница 2: ...bs maximum on straight 330lbs maximum on corner 4 The input voltage should be within 108 132V 5 Use the glides to properly level the table before use Table should be level and aligned at all times 6 B...

Страница 3: ...t K Socket Button Head Bolt M6 20mm 12 L Socket Button Head Bolt M6 12mm 20 M Wire Manager 4 N Truss Head Screw M5 20mm 34 Parts List Installation Steps Step 1 Place worksurface finished side down on...

Страница 4: ...g steps 3 4 Remove pad when done Step 7 Place all 3 leg assemblies on worksurface and insert E center rails into D crossbeams as shown Hole on center rails should be centered between crossbeams Center...

Страница 5: ...s shown below Step 11 Secure the F control panel in the desired location with N 2 truss head screws M5 20mm Insert the G control box in between crossbeams Step 11a With post foot option as shown below...

Страница 6: ...owest to 50 highest Step 14 Turn table right side up adjust the glides as necessary and plug the power cord into a 110v outlet Step 13 Install the H telescopic cover plates leaving exit space for the...

Страница 7: ...em is locked Various Reasons 1 Remove plug from electrical outlet for 15 seconds then plug unit back in 2 Perform reset operation 3 If problem persists contact Friant customer service to replace contr...

Отзывы: