TDR
7/8
P
eco
Gas
EN
44
/
48
8.
MALFUNCTIONS AND SERVICE
Before you contact your supplier/dealer in case of a malfunction, there are some items you
can check yourself:
Is the power supply working properly? Check fuses and differential switch.
Is the gas supply in good order?
Has the timer clock been properly set?
Item
Malfunction
Possible action
Control
Program do not start
Check if both doors are closed
correctly.
Fan
ONE fan not spinning
Remove the plug from the
socket.
Open the door.
Remove fan plate (see section
7.4) and check what's blocking
the fan blade.
Fan
ALL fans not spinning
Open and close door
Fan Noisy
fan
Fan polluted, clean (see
section 7.4).
Lamp
Does not light up
Set OFF in manager menu.
Door is open.
Defect, refer to section 8.3
.
Oven
Product is not getting done equally
Try a lower cooking
temperature.
Oven
The oven does not heat up
Open and close door.
Check fuses and/or the
differential switch in the
electricity board.
Oven
The light of the burner failure light
up when starting the TDR
When the gas supply has been
disconnected and the supply
has not been bled afterwards,
some air may be left in the
supply. Bleed the supply.
Press the reset button for a
few seconds.
Oven
The light of the burner failure light
up during the grilling process
If a failure is observed, fix the
gas supply. Press the reset
button for a few seconds.
Mains cord
Damaged
Replace, see section 8.1
Gas hose
Damaged
Replace, see section 8.2
8.1.
Replace the mains cord
WARNING
Hazardous electrical voltage.
If the mains cord is damaged, it must be replaced by the manufacturer, his service agent or a
similarly qualified person in order to avoid hazards.
Содержание TDR 7