Page 6
Service Manual LDR 8s AC
PKII
form 9120934 rev. 02/2022
LDR 8S AC INSTALLATION
LDR 8S AC GAS, TECHNICAL DATA
American models
Model
s
LDR 8 s AC Gas
Dimensions approx.
Width
inch
52
Depth
inch
38 ¼
Height
inch
71½
Weight
Gross
lbs.
800
Net
lbs.
690
Maximum ambient
temperature
°F
95
Sound pressure
dB (A)
< 70
Electrical installation
Voltage
V
1~ 208
Frequency
Hz
50/60
Required power
kW
0.9
Max. nominal
current
A
4.4
Plug
NEMA
6 - 15P
Power cable
Length
inch
75
Water connection
Aerated
inch
¾ (1x)
Water
pressure
kPa
200 – 500
Acidity
pH
7.0 - 8.0
Chlorides
ppm
<30
Hardness ¹
dH
<4
Drain
Open connection
inch
min. 1⅝
Gas System
Refer to data plate
Power rating (max)
BTU / KW
82.000 / 24
Connection
Inch NPT
½
Gas specification
Consumption ²
Gas pressure min/max
Natural gas
2.2 mᶟ/hr
7”wc (17 mbar)/14”wc (35mbar)
1) See chapter “water requirements” for detailed information
2) At sea level 1013 mbar 20°C
Consult the identification plate to get the proper specifications of the rotisserie. The electrical data may
vary from
country to country.
All of the information, illustrations and specifications contained in this manual are based on the latest
product information available at the time of printing.
Содержание LDR 8s AC Gas
Страница 2: ...Page 2 TABLE OF CONTENTS Service Manual LDR 8s ACPKII form 9120934 rev 02 2022 EMPTY PAGE EMPTY PAGE ...
Страница 50: ...Page 50 SERVICE PROCEDURES Service Manual LDR 8s ACPKII form 9120934 rev 02 2022 ...
Страница 85: ...Service Manual LDR 8s ACII form 9120934 rev 02 2022 ...
Страница 86: ...Service Manual LDR 8s ACPKII form 9120934 rev 02 2022 ...