SOFTWARE
Page 39
Service Manual LDR 8s AC
II
form 9120934 rev. 02/2022
Level 1
Level 2
Level 3
Hood
Option to activate the optional hood
PID factors
P
Temperature regulation setting (P= proportional)
I
Temperature regulation setting (I= Integrating)
D
Temperature regulation setting (D= Differentiating)
iMax
Temperature regulation setting
Relay acti-
ons:
Controlls the amount of relay switches in time
Gas burner settings
Gas T safety
At this temperature or higher, the power in the burner will be decreased, to protect the
burner.
Gas P threshold
When the above temperature is reached, the burner will be switched back to this power
value
Gas P minimum
When less than this power value is needed, the burner will be switched off.
Energy
Volts
Set the actual voltage
Machine
model
I/O test
Analog input
Digital inputs
read the inputs of; door (J13), Clickson Blower (J14), Hood filter placement (J15), Hood filter
press diff (J16)
Digital out-
puts
Set the ouputs of; Rotor (M1), Blower (M2), Heater (K1), Light (K2), Water supply (W1),
Backflush water (W2), Water pump (K6), Drain valve (Q5), Casco (Q1), Spray right (Q2),
Spray left (Q3), Fat drain (Q4)
Board Feed-
back
Read feedback value
Board Ver-
sion
Read board version
Board Variant Read board variant
Test program
Yes activates a cleaning cycle
Ignore errors
If set to yes the controller does not show errors
save HACCP
Option to save the HACCP log to a USB key
HACCP days
Option to set the amount of days the HACCP log stores
save params on
USB
Copy parameters from the rotisserie to the USB key.
save params from
USB
Load parameters from a USB key to the rotisserie.
Initial heat up time
Recorded heat up time during initial cook
Actual heat up
time
Recorded heat up time during last cook
Heat up program
Yes activates the heat up program and shows the heatup time in seconds. Note: if the oven
is to hot when the heatup is activated it will cool down first
Heat up time reset
Resets the recorded heatup times
Lights out
Option to disable or enable the interiour lights during the cook
Wifi Smartphone
Optin to allow a connection to an Smartphone
Wifi smart Cloud
Option to enable a connection to the Fri-Jado Smart Connect website.
Wifi RSSI
Shows the signal level of the WiFi connection. Values are between -101dBm and -1dBm. In
practice values are between -85dBm and -25dBm. A bad connection would give -85dBm, a
very good connection would give -25dBm.
Wifi Auto Restart
"If you set a time of >= 5 minutes here, the machine will regularly check whether the WiFi no
longer receives messages during the set time interval.
In case there was no communication during that time interval, the WiFi communication will
be restarted. This is intended to be able to automatically recover any loss of the WiFi con-
nection if there should be long-term problems."
Start Config
"This allows you to force the machine to start a new cloud configuration.
The old WiFi access point data will be deleted at that time and after a few seconds a smart-
phone symbol will appear in the top right corner of the status bar on the screen. From the
moment that smartphone symbol appears, the user can set the cloud configuration on the
machine via the smartphone."
Reset Wifi Chip
This option resets the wifi chip with an electronic reset signal and restarts the wifi communi
-
cation in the software.
Fact reset settings
Reset to factory settings
Содержание LDR 8s AC Gas
Страница 2: ...Page 2 TABLE OF CONTENTS Service Manual LDR 8s ACPKII form 9120934 rev 02 2022 EMPTY PAGE EMPTY PAGE ...
Страница 50: ...Page 50 SERVICE PROCEDURES Service Manual LDR 8s ACPKII form 9120934 rev 02 2022 ...
Страница 85: ...Service Manual LDR 8s ACII form 9120934 rev 02 2022 ...
Страница 86: ...Service Manual LDR 8s ACPKII form 9120934 rev 02 2022 ...