10.2. RUNNING THE FIBER BLOWING MACHINE
•
Prepare the fiber cable and place it inside the
fiber blowing machine. Adjust the drive wheels
until they are tight around the fiber cable
•
Place the microduct, which the fiber cable is to
be blown into, in the blowing junction block
•
Close the lid and tighten the screws on top
•
On the TOUCH screen:
•
Set the desired speed (m/min)
•
Set the torque level to the desired
maximum
•
OPTIONAL: The pre-set meter counter can
be used to stop the machine after a given
distance (set to “0” and the machine will
continue indefinitely)
•
Press the ON/OFF button, and the machine will
accelerate to the pre-set maximum speed
After 10-20 meters, turn on air. Gradually increase
air supply as the blowing is proceeding.
•
The blowing is now running automatically
•
If the machine stops unintentionally, there are
two adjustable parameters:
•
increase air supply
•
or reduce speed if there is no more air
pressure
•
Stop the machine, either manually or when
reaching the pre-set distance
•
Turn off air
•
The lid can be opened when the air pressure
gauge is at “0” bar/psi
WARNING
: Do not open the
machine while under pressure, as this
may damage the machine and cause
personal injury.