External A/C Condenser
Inspection and Cleaning
On vehicles manufactured from July 2011, the
ParkSmart A/C condenser is located on the backwall
of the sleeper. Inspect the condenser as follows.
1.
Remove the inspection plate on the bottom of
the condenser module. See
Fig. 15
.
NOTE: If the condenser core has a build up of
fine debris, an A/C core cleaner, approved for
copper and aluminum cores, and a low pressure
water can be use to clean it.
2.
Clean out any debris in the module.
3.
Install the inspection plate.
09/21/2010
f831857
1
2
Remove and clean the drain tube.
1.
Drain Tube
2.
Intake Duct
Fig. 13, Drain Tube Inspection (pre-July 2011)
06/10/2011
f831880
Remove and clean the drain tubes.
Fig. 14, Drain Tube Inspection (from July 2011)
06/10/2011
f831879
Remove the inspection plate.
Fig. 15, Condenser Cleaning
Heater and Air Conditioner
83
Cascadia Maintenance Manual, August 2015
83/6