FCC Statement 

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) thi 
s device may not cause harmful interference, and (2) this device must accept any interference received, incl 
uding interference that may cause undesired operation. 
Changes or modifications not expressly approved by the party responsible for compliance could void the us

er’ 

s authority to operate the equipment. 
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursua 
nt to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inte 
rference in a residential installation. This equipment generates uses and can radiate radio frequency energy a 
nd, if not installed and used in accordance with the instructions, may cause harmful interference to radio com 
munications. However, there is no guarantee that interference will not occur in a particular installation. If this 
equipment does cause harmful interference to radio or television reception, which can be determined by turn 
ing the equipment off and on, the user is encouraged to try to correct the interference by one or more of the 
following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

Consult the dealer or an experienced radio/TV technician for help important announcement 

Important Note: 

Radiation Exposure Statement 

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This 
equipment should be installed and operated with minimum distance 0cm between the radiator and your 
body. 
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 
Country Code selection feature to be disabled for products marketed to the US/Canada. 
This device is intended only for OEM integrators under the following conditions: 

1.

 

The antenna must be installed such that 0 cm is maintained between the antenna and users, and 

2.

 

The transmitter module may not be co-located with any other transmitter or antenna, 

As long as the three conditions above are met, further transmitter testing will not be required. However, the 
OEM integrator is still responsible for testing their end-product for any additional compliance requirements 
required with this module installed. 

 

Important Note: 

In  the event  that  these  conditions  cannot  be  met  (for example  certain laptop configurations  or  co-location 
with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID cannot be 
used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the 
end product (including the transmitter) and obtaining a separate FCC authorization. 

 

End Product Labeling 

The final end product must be labeled in a visible area with the following" Contains FCC ID: 

2A4TN-FN-RFID-

RC522

 

Manual Information to the End User 

The OEM integrator has to be aware not to provide information to the end user regarding how to install or 

remove this RF module in the user’s manual of the end product which integrates this module.

 

The end user manual shall include all required regulatory information/warning as show in this manual. 

Содержание RFID-RC522

Страница 1: ...munication technology Project 1 Read UID In this project we will read the unique ID number UID of the RFID card recognize the type of the RFID card and display the information through serial port Component List Freenove UNO x1 RC522 RFID Module x1 Mifare1 S50 Standard card x1 Mifare1 S50 Non standard card x1 USB able x1 Jumper F M x7 ...

Страница 2: ...he main operating frequency of Passive RFID products are 125KHZ low frequency 13 56MHZ high frequency 433MHZ ultrahigh frequency 915MHZ ultrahigh frequency Active and semi active RFID products work at higher frequencies The RFID module we use is a passive RFID product with the operating frequency of 13 56MHz Component Knowledge MFRC522 RFID Module The MFRC522 is a highly integrated reader writer I...

Страница 3: ...lobal unique identifier number USN UID which can be rewritten 100 thousand times and read infinite times Its storage period can last for 10 years The ordinary Mifare1 S50 Card and non standard Mifare1 S50 Card equipped for this kit are shown below Mifare1 S50 Standard card Mifare1 S50 Non standard card The Mifare1 S50 capacity 1K byte is divided into 16 sectors Sector0 Sector15 Each sector contain...

Страница 4: ...ontrol block including a 6 byte password A 4 byte access control and 6 byte password B For example the control block of a brand new card is as follows A0 A1 A2 A3 A4 A5 FF 07 80 69 B0 B1 B2 B3 B4 B5 password A access control password B The default password of a brand new card is generally A0A1A2A3A4A5 for password A B0B1B2B3B4B5 for password B or both the password A and password B are 6 FF Access ...

Страница 5: ...5 RFID www freenove com Circuit The connection of Freenove UNO board and RFID module is shown below Schematic diagram Hardware connection ...

Страница 6: ... char str MAX_LEN MAX_LEN is 16 size of the array void setup Serial begin 9600 SPI begin rfid init initialization Serial println Please put the card to the induction area void loop Search card return card types if rfid findCard PICC_REQIDL str MI_OK Serial println Find the card Show card type ShowCardType str Anti collision detection read card serial number if rfid anticoll str MI_OK Serial print ...

Страница 7: ... to the SDA pin and the RST pin 5 RFID rfid 10 9 In setup initialize the serial port SPI and RFID 11 12 13 Serial begin 9600 SPI begin rfid init initialization In loop use findCard waiting for the card approaching Once it detects card contact this function will return MI_OK and save the card type data in parameter str Then enter the if statement 20 if rfid findCard PICC_REQIDL str MI_OK After ente...

Страница 8: ...NO open the serial port monitor and make a card approach the sensing area of RFID module Then serial port monitoring window will display the displacement ID number and the type of the card If the induction time is too short it may lead to incomplete information display ...

Страница 9: ...es with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 0cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Country Code selection feature to be disabled for products marketed to the US Canada This device is inten...

Страница 10: ...r your body 2 7 Antennas This radio transmitter FCC ID 2A4TN FN RFID RC522 has been approved by Federal Communications Commission to operate with the antenna types listed below with the maximum permissible gain indicated Antenna types not included in this list that have a gain greater than the maximum gain indicated for any type listed are strictly prohibited for use with this device Antenna No Mo...

Страница 11: ...é avec rss 102 de l exposition aux rf les utilisateurs peuvent obtenir des données canadiennes sur l exposition aux champs rf et la conformité This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment Cet équipement est conforme Canada limites d exposition aux radiations dans un environnement non contrôlé This equipment should be installed and operated...

Отзывы: