Integration instructions for host product manufacturers according to KDB 996369 D03 OEM 
Manual v01 
2.2 List of applicable FCC rules 

 

CFR 47 FCC PART 15 SUBPART C has been investigated. It is applicable to the modular transmitter 

2.3 Specific operational use conditions 

 

This  module  is  stand-alone  modular.  If  the  end  product  will  involve  the  Multiple  simultaneously  transmitting  condition  or  different 
operational conditions for a stand-alone modular transmitter in a host, host manufacturer have to consult with module manufacturer 
for the installation method in end system. 

 

2.4 Limited module procedures 

Not applicable 

2.5 Trace antenna designs 

Not applicable 

2.6 RF exposure considerations 

 

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be 
installed and operated with minimum distance 20cm between the radiator & your body. 

 

2.7 Antennas 

This  radio  transmitter  FCC  ID:

2A4TN-FN-RFID-RC522 

has  been  approved  by  Federal  Communications  Commission  to  operate 

with the 
antenna types listed below, with the maximum permissible gain indicated. Antenna types not included in this list that have a gain 
greater than the maximum gain indicated for any type listed are strictly prohibited for use with this device. 
 

Antenna No. 

Model No. of 

antenna: 

Type of antenna: 

Gain of the antenna (Max.) 

Frequency range: 

NFC  

Loop Antenna 

0dBi for 13.56MHz; 

 
 

2.8 Label and compliance information 

The final end product must be labeled in a visible area with the following" Contains FCC ID:

 

2A4TN-FN-RFID-RC522". 

2.9 Information on test modes and additional testing requirements 

Host manufacturer is strongly recommended to confirm compliance with FCC requirements for the transmitter when the module is 
installed in the host. 

2.10 Additional testing, Part 15 Subpart B disclaimer 

Host manufacturer is responsible for compliance of the host system with module installed with all other applicable requirements for 

the system such as Part 15 B. 

Содержание RFID-RC522

Страница 1: ...munication technology Project 1 Read UID In this project we will read the unique ID number UID of the RFID card recognize the type of the RFID card and display the information through serial port Component List Freenove UNO x1 RC522 RFID Module x1 Mifare1 S50 Standard card x1 Mifare1 S50 Non standard card x1 USB able x1 Jumper F M x7 ...

Страница 2: ...he main operating frequency of Passive RFID products are 125KHZ low frequency 13 56MHZ high frequency 433MHZ ultrahigh frequency 915MHZ ultrahigh frequency Active and semi active RFID products work at higher frequencies The RFID module we use is a passive RFID product with the operating frequency of 13 56MHz Component Knowledge MFRC522 RFID Module The MFRC522 is a highly integrated reader writer I...

Страница 3: ...lobal unique identifier number USN UID which can be rewritten 100 thousand times and read infinite times Its storage period can last for 10 years The ordinary Mifare1 S50 Card and non standard Mifare1 S50 Card equipped for this kit are shown below Mifare1 S50 Standard card Mifare1 S50 Non standard card The Mifare1 S50 capacity 1K byte is divided into 16 sectors Sector0 Sector15 Each sector contain...

Страница 4: ...ontrol block including a 6 byte password A 4 byte access control and 6 byte password B For example the control block of a brand new card is as follows A0 A1 A2 A3 A4 A5 FF 07 80 69 B0 B1 B2 B3 B4 B5 password A access control password B The default password of a brand new card is generally A0A1A2A3A4A5 for password A B0B1B2B3B4B5 for password B or both the password A and password B are 6 FF Access ...

Страница 5: ...5 RFID www freenove com Circuit The connection of Freenove UNO board and RFID module is shown below Schematic diagram Hardware connection ...

Страница 6: ... char str MAX_LEN MAX_LEN is 16 size of the array void setup Serial begin 9600 SPI begin rfid init initialization Serial println Please put the card to the induction area void loop Search card return card types if rfid findCard PICC_REQIDL str MI_OK Serial println Find the card Show card type ShowCardType str Anti collision detection read card serial number if rfid anticoll str MI_OK Serial print ...

Страница 7: ... to the SDA pin and the RST pin 5 RFID rfid 10 9 In setup initialize the serial port SPI and RFID 11 12 13 Serial begin 9600 SPI begin rfid init initialization In loop use findCard waiting for the card approaching Once it detects card contact this function will return MI_OK and save the card type data in parameter str Then enter the if statement 20 if rfid findCard PICC_REQIDL str MI_OK After ente...

Страница 8: ...NO open the serial port monitor and make a card approach the sensing area of RFID module Then serial port monitoring window will display the displacement ID number and the type of the card If the induction time is too short it may lead to incomplete information display ...

Страница 9: ...es with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 0cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Country Code selection feature to be disabled for products marketed to the US Canada This device is inten...

Страница 10: ...r your body 2 7 Antennas This radio transmitter FCC ID 2A4TN FN RFID RC522 has been approved by Federal Communications Commission to operate with the antenna types listed below with the maximum permissible gain indicated Antenna types not included in this list that have a gain greater than the maximum gain indicated for any type listed are strictly prohibited for use with this device Antenna No Mo...

Страница 11: ...é avec rss 102 de l exposition aux rf les utilisateurs peuvent obtenir des données canadiennes sur l exposition aux champs rf et la conformité This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment Cet équipement est conforme Canada limites d exposition aux radiations dans un environnement non contrôlé This equipment should be installed and operated...

Отзывы: